https://bugs.kde.org/show_bug.cgi?id=485022

            Bug ID: 485022
           Summary: Wireplumber crashes when the window/screen my portal
                    is capturing is removed and I change volume level
    Classification: Plasma
           Product: xdg-desktop-portal-kde
           Version: 6.0.3
          Platform: Other
                OS: Linux
            Status: REPORTED
          Severity: crash
          Priority: NOR
         Component: general
          Assignee: plasma-b...@kde.org
          Reporter: brodierobertson54...@gmail.com
                CC: aleix...@kde.org, jgrul...@redhat.com, n...@kde.org
  Target Milestone: ---

Created attachment 168141
  --> https://bugs.kde.org/attachment.cgi?id=168141&action=edit
Attached pipewire log

SUMMARY
I'm not entirely what in the chain is at fault here

If I am capturing a window/screen inside of OBS using the KDE portal on the
Plasma Wayland session, then I remove that window (by closing it) or that
screen (by switching the output of my monitor) but the I don't update what the
portal is capturing. If I change my volume level wireplumber instantly
segfaults. This only occurs when I am making use of the portal that's why I
thought maybe it's a KDE problem, also KDE is mentioned in the pipewire log


STEPS TO REPRODUCE
1. Open OBS
2. Begin capturing a window with the portal
3. Close that window
4. Change your volume level
5. Wireplumber crashes

OBSERVED RESULT
All audio input and output breaks and takes a moment until wireplumber comes
back, however pipewire video capture continues going


EXPECTED RESULT
Things not crashing


SOFTWARE/OS VERSIONS

Linux: Arch Linux
KDE Plasma Version: 6.03
KDE Frameworks Version: 6.0.0
Qt Version: 6.6.3

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to