https://bugs.kde.org/show_bug.cgi?id=469568

            Bug ID: 469568
           Summary: In Plasma 6 with a floating panel, input redirecting
                    around empty areas fails if the cursor is farther than
                    the default drag distance
    Classification: Plasma
           Product: plasmashell
           Version: master
          Platform: Other
                OS: Linux
            Status: REPORTED
          Keywords: qt6
          Severity: normal
          Priority: NOR
         Component: Panel
          Assignee: plasma-b...@kde.org
          Reporter: n...@kde.org
                CC: niccolo.venera...@gmail.com
  Target Milestone: 1.0

STEPS TO REPRODUCE
1. Be in Plasma 6
2. Make your panel floating
3. Move cursor all the way to screen edge near a Task Manager icon and click

OBSERVED RESULT
Task Manager icon starts to get dragged

EXPECTED RESULT
Task Manager icon activated

SOFTWARE/OS VERSIONS
Operating System: Fedora Linux 38
KDE Plasma Version: 5.27.80
KDE Frameworks Version: 5.240.0
Qt Version: 6.5.0
Kernel Version: 6.2.14-300.fc38.x86_64 (64-bit)
Graphics Platform: offscreen
Processors: 8 × Intel® Core™ i7-10510U CPU @ 1.80GHz
Memory: 15.2 GiB of RAM
Graphics Processor: Mesa Intel® UHD Graphics

ADDITIONAL INFORMATION
If I move the cursor two pixels closer to the panel, it works properly. So a
horrible hacky workaround could be to increase the global drag distance.

This is a minor Fitts' Law violation.

-- 