https://bugs.kde.org/show_bug.cgi?id=464898
Bug ID: 464898 Summary: Misplaced popups when screen is added after plasma started Classification: Plasma Product: plasmashell Version: 5.26.90 Platform: openSUSE OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: Multi-screen support Assignee: plasma-b...@kde.org Reporter: conf...@gmail.com CC: aleix...@kde.org, notm...@gmail.com Target Milestone: 1.0 SUMMARY When a new display is added after plasmashell has already started, any popups and tooltips will be placed on the new screen instead of their intended location. STEPS TO REPRODUCE 1. Start Plasma with a single screen active 2. Add a panel to the active screen 3. Add the system tray to the panel 4. Plug in or power on a new screen 5. Click any entry in the system tray excluding the night color control OBSERVED RESULT The popup appears on the leftmost edge of the new screen disconnected from its panel. EXPECTED RESULT The popup appears directly above the panel containing clicked entry. SOFTWARE/OS VERSIONS Linux/KDE Plasma: openSUSE Tumbleweed 20230125 KDE Plasma Version: 5.26.90 KDE Frameworks Version: 5.15.8 Qt Version: 5.15.8 ADDITIONAL INFORMATION On very rare occasions, the bug does not occur when performing the steps below. To reproduce, the steps may have to be repeated. -- You are receiving this mail because: You are watching all bug changes.