https://bugs.kde.org/show_bug.cgi?id=444277

            Bug ID: 444277
           Summary: Incorrect charge stop percentage shown (percentage
                    copied from first battery "BAT0")
           Product: plasmashell
           Version: 5.23.0
          Platform: Neon Packages
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: Battery Monitor
          Assignee: k...@privat.broulik.de
          Reporter: m...@mailmailmail.tk
                CC: plasma-b...@kde.org
  Target Milestone: 1.0

Created attachment 142797
  --> https://bugs.kde.org/attachment.cgi?id=142797&action=edit
Incorrect charge_stop_threshold value for the second and mouse battery

SUMMARY

The incorrect charge stop percentage is shown for all except the first battery.

The battery at /sys/class/power_supply/BAT0 has set its charge_stop_threshold
to 50% and /sys/class/power_supply/BAT0 to 72%, but all batteries (as well as
my mouse battery) show the percentage as 50% which is incorrect.

Also it shows both batteries as charging even though they're not charging,
status is "Unknown"

See the attached screenshot

STEPS TO REPRODUCE
1. Have multiple batteries in your system
2. Click on the battery tray icon

OBSERVED RESULT

All charge stop percentages are the same as BAT0


EXPECTED RESULT

The first is 50% which is correct, but the second should be 72 % and the mouse
doesn't even have a charge_stop_threshold value so it should not show any
percentage.

SOFTWARE/OS VERSIONS

Linux/KDE Plasma: 5.23.0 
KDE Plasma Version:  5.23.0 
KDE Frameworks Version: 5.87.0
Qt Version: 5.13.3

ADDITIONAL INFORMATION
This was tested on KDE Neon 


Thanks

-- 