https://bugs.kde.org/show_bug.cgi?id=427874
Bug ID: 427874 Summary: Sensors for external devices get removed when device is not present Product: ksysguard Version: 5.19.5 Platform: Other OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: ksysguard Assignee: ksysguard-b...@kde.org Reporter: fonic.max...@live.com CC: plasma-b...@kde.org Target Milestone: --- Created attachment 132482 --> https://bugs.kde.org/attachment.cgi?id=132482&action=edit Attachment 1: Tab file before I frequently use several external devices for video editing. To monitor them, I created a tab for ksysguard (see attachment 1). When I open and close ksysguard, all sensors for devices that are currently not attached to the system get automatically erased from the tab file (see attachment 2). In other words, there seems to be no way to create a tab containing sensors for devices that are not guaranteed to be present at all times (i.e. external/removable devices). STEPS TO REPRODUCE 1. Open ksysguard 1. Add tab from file (see attachment 1) 2. Close ksysguard 3. Open imported tab file in editor, sensors for devices currently not present should now have been erased (similar to attachment 2) OBSERVED RESULT Sensors for devices that are not present when ksysguard is opened/closed are erased automatically from the tab file. EXPECTED RESULT Sensors for devices that are not present when ksysguard is opened/closed should not be erased automatically, at least there should be a configuration option to toggle this. SOFTWARE/OS VERSIONS Operating System: Gentoo Linux KDE Plasma Version: 5.19.5 KDE Frameworks Version: 5.74.0 Qt Version: 5.15.1 Kernel Version: 5.4.66-gentoo OS Type: 64-bit -- You are receiving this mail because: You are watching all bug changes.