https://bugs.kde.org/show_bug.cgi?id=422537

            Bug ID: 422537
           Summary: Volume level OSD and popup of plasma-pa applet show
                    different percentages if "Raise maximum volume" is
                    enabled
           Product: plasmashell
           Version: master
          Platform: Neon Packages
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: k...@davidedmundson.co.uk
          Reporter: bugsefor...@gmx.com
                CC: plasma-b...@kde.org
  Target Milestone: 1.0

Created attachment 129104
  --> https://bugs.kde.org/attachment.cgi?id=129104&action=edit
screenshot

STEPS TO REPRODUCE
1. click on volume icon in system tray
2. enable "Raise maximum volume"
3. while the popup of plasma-pa applet is still open, change the volume level
by scrolling on the sound icon in system tray

OBSERVED RESULT
as we can see in the attached screenshot, volume level OSD and popup of
plasma-pa applet show different percentages

EXPECTED RESULT
volume level OSD and popup of plasma-pa applet should show the same percentage

SOFTWARE/OS VERSIONS
Operating System: KDE neon Unstable Edition
KDE Plasma Version: 5.19.80
KDE Frameworks Version: 5.71.0