https://bugs.kde.org/show_bug.cgi?id=408331

--- Comment #13 from Ahab Greybeard <ahab.greybe...@hotmail.co.uk> ---
Using the 4.2.1 and later portable .zip packages on Windows 10, I find that the
bug will happen with any brush preset if the last preset that was used is used
immediately after starting krita. After using another preset, the bug goes away
until next restart. If any other preset is selected first then the bug does not
happen. 

If the line "LastPreset={preset name}" is removed from the kritarc file before
starting krita, the bug will not happen until after a brush preset use, then a
quit and restart.

It's the same as in the appimages except that it happens with any brush preset.

This happens with OpenGL as well as with Angle.

Using an appimage, I made a copy of 'b) Basic_1' and the copy did not show the
bug when krita was started if it was the last brush preset used before Quiting.

The observations made by cadaverous.doll, in
https://bugs.kde.org/show_bug.cgi?id=408554, regarding the behaviour of the
brush editor's 'Reload' icon also hold true for what I've seen.

-- 
You are receiving this mail because:
You are watching all bug changes.