https://bugs.kde.org/show_bug.cgi?id=402163
Bug ID: 402163
Summary: Cooling of ASI stops 1.5C before target temp (ZWO
ASI1600MM Pro)
Product: kstars
Version: 2.9.8
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
Target Milestone: ---
Created attachment 116940
--> https://bugs.kde.org/attachment.cgi?id=116940&action=edit
Temp setting
SUMMARY
Start cooling in CCD Menu. Set to 0°C (or any other Temp x). The temp drops to
1.5°C (or x+1.5°C) displayed in EKOS. However, the temp drops below target
uncontrolled (as observed by disconnecting and reconnecting immediately, see
screen shot 2)
Temperature control works perfectly under Windows.
STEPS TO REPRODUCE
1. Connect ASI1600MM
2. Set temp to x and press "set"
3. Observe temperature
OBSERVED RESULT
Temp displayed is x+1.5°C
After reconnecting CCD (fast) temp << x (not controlled)
EXPECTED RESULT
Temperature x°C