Anyone ever seen this alarm on an MX304 following a Junos upgrade?

I went from ...

22.2R3-S1.9 - initially had this
22.4R2-S2.6 - upgrade
23.2R1-S2.5 - final

now with23.2R1-S2.5, i have an issue with more than one, 100g interfaces being able to operate.  I have a 100g on et-0/0/4 and another one on et-0/0/12... BUT, they won't both function at the same time.  4 works, 12 doesn't... reboot mx304, 4 doesn't work, but 12 does. Very weird.

root@304-1> show system alarms
6 alarms currently active
Alarm time               Class  Description
2024-02-29 06:00:25 CST  Minor  200 ADVANCE Bandwidth (in gbps)s(315) require a license
2024-02-29 06:00:25 CST  Minor  OSPF protocol(282) usage requires a license
2024-02-29 06:00:25 CST  Minor  LDP Protocol(257) usage requires a license
2024-02-28 09:35:10 CST  Minor *FPC 0 firmware outdated*
2024-02-28 09:29:45 CST  Major  Host 0 fxp0 : Ethernet Link Down
2024-02-28 09:28:15 CST  Major  Management Ethernet Links Down


root@304-1> show chassis alarms
3 alarms currently active
Alarm time               Class  Description
2024-02-28 09:35:10 CST  Minor *FPC 0 firmware outdated*
2024-02-28 09:29:45 CST  Major  Host 0 fxp0 : Ethernet Link Down
2024-02-28 09:28:15 CST  Major  Management Ethernet Links Down


--
-Aaron
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to