Hello everyone.

We have used the QFX5120 with L2circuit for long. Now in version 19.4R3-S2 it 
is possible to use this this function in aggregate interfaces. Log time effort 
to get this function back again.  For both 48Y and 32C.

The balancing feature is supported only by DLB for now (not FAT or EL)

You also need to understand the need for policers in tunnels. Types of 
signaling and tunnel scalability, depending on chipset (T3).

But they work well for some limited projects.

The suggestion is to ask your SE for a POC and approve everything you need, in 
addition to testing scalability.

See the new ACX7100-48L and ACX7100-32C housings that are coming out with J2. 
They look interesting and promising (features and scalability)

We should test them soon.

Att,

Giuliano

-----Original Message-----
From: juniper-nsp <[email protected]> On Behalf Of 
[email protected]
Sent: sexta-feira, 16 de abril de 2021 17:03
To: 'Colton Conor' <[email protected]>
Cc: 'Juniper List' <[email protected]>
Subject: Re: [j-nsp] ACX Questions

I run martini rfc 4447 ldp-based l2circuits as well as vpls on our mx204's and 
also acx5048's (I think junos 15.x and 17.x on 5048 and I think it's 18.x on 
204)...  I don't think I've tried mpls on qfx5120 (not sure what version of 
gfx5100) you use.



I just tried to lab up l2circuit on one of my qrx5120's and I get a license 
error for mpls feature



-Aaron





From: Colton Conor <[email protected]>
Sent: Friday, April 16, 2021 2:30 PM
To: Aaron <[email protected]>
Cc: Juniper List <[email protected]>
Subject: Re: [j-nsp] ACX Questions



I just received an off list email stating that the ACX5048 does support 
l2circuit (LDP signaled). Is this the same feature as Ethernet-over-MPLS (L2 
circuit)? If so why is it showing this feature is not supported on ACX (or MX 
for that matter)? Is the feature explorer incorrect? 
https://nam02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fapps.juniper.net%2Ffeature-explorer%2Ffeature-info.html%3FfKey%3D6620&amp;data=04%7C01%7Cgiuliano%40wztech.com.br%7Ca894125d52644bd4059a08d901135ff1%7C584787b077bd4312bf8815412b8ae504%7C1%7C0%7C637542005056267763%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&amp;sdata=mUclh7UDnl4BX4nIirdM5FFbtR9SKMC01iWHDMNqUtQ%3D&amp;reserved=0
 
<https://nam02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fapps.juniper.net%2Ffeature-explorer%2Ffeature-info.html%3FfKey%3D6620%26fn%3DEthernet-over-MPLS%2520&amp;data=04%7C01%7Cgiuliano%40wztech.com.br%7Ca894125d52644bd4059a08d901135ff1%7C584787b077bd4312bf8815412b8ae504%7C1%7C0%7C637542005056267763%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&amp;sdata=cm1%2FqV2VK7dmi9ZV2Xhg%2BnKRTdyzeg30E8uCW%2BY1e%2FA%3D&amp;reserved=0(L2%20circuit)>
 &fn=Ethernet-over-MPLS%20(L2%20circuit)



I do see

20.3R1

Starting in Junos OS Release 20.3R1, support for Layer 2 circuit to provide 
Layer 2 VPN and VPWS with LDP signaling.



On Fri, Apr 16, 2021 at 8:52 AM Colton Conor <[email protected] 
<mailto:[email protected]> > wrote:

Thanks all for this information. Aaron I had my client run this same command on 
their QFX5100, and it too has max 3 labels. It seems the issue is that the 
client needs a layer 2 transport over a layer 3 network. VPLS is the logical 
choice, and the ACX5048 supports this according to the Juniper Feature 
Explorer. The QFX5100, however, does not. What layer 2 over Layer 3 option do 
you recommend for the QFX5100 to talk to an ACX5048 or MX204 on the other end?
It looks like the QFX5100 supports Ethernet-over-MPLS (L2 circuit). Is this an 
alternative to VPLS? ACX and MX does not support Ethernet-over-MPLS (L2 
circuit) however. It seems there is no common protocol that both the QFX and 
ACX/MX share in common under the Virtual Private Networks (VPNs) section of the 
feature explorer. Is there any solution other than replacing the QFX with ACX's 
or MX's?

https://nam02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fapps.juniper.net%2Ffeature-explorer%2Fselect-platform.html%3Fcategory%3DSwitching&amp;data=04%7C01%7Cgiuliano%40wztech.com.br%7Ca894125d52644bd4059a08d901135ff1%7C584787b077bd4312bf8815412b8ae504%7C1%7C0%7C637542005056267763%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&amp;sdata=qcEcr9DPea9gt6KJoq6EOsNQDEuMWdPaOKaBbcjvvu8%3D&amp;reserved=0
 
<https://nam02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fapps.juniper.net%2Ffeature-explorer%2Fselect-platform.html%3Fcategory%3DSwitching%26typ%3D1%23family%3D%26pid%3D31705100%26platform%3DQFX5100%26rel%3D20.4R1%26sid%3D1093%26stat%3D0.10700692867685069%26swName%3DJunos%2520OS&amp;data=04%7C01%7Cgiuliano%40wztech.com.br%7Ca894125d52644bd4059a08d901135ff1%7C584787b077bd4312bf8815412b8ae504%7C1%7C0%7C637542005056267763%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&amp;sdata=AgFrEbgOojxzSSE35CHsaFgxwgTKQhSVkNNo3eELWCY%3D&amp;reserved=0>
 
&typ=1#family=&pid=31705100&platform=QFX5100&rel=20.4R1&sid=1093&stat=0.10700692867685069&swName=Junos%20OS





On Wed, Apr 14, 2021 at 12:51 AM <[email protected] <mailto:[email protected]> > 
wrote:

Of the interfaces configured for mpls on this acx, they show max labels 3



me@5048> show mpls interface detail | grep "Interface|labels"
Interface: ae0.0
  Maximum labels: 3
Interface: ae40.0
  Maximum labels: 3
Interface: xe-0/0/0.0
  Maximum labels: 3
Interface: ge-0/0/3.0
  Maximum labels: 3
Interface: ge-0/0/5.0
  Maximum labels: 3
Interface: ge-0/0/13.0
  Maximum labels: 3
Interface: ge-0/0/18.0
  Maximum labels: 3
Interface: ge-0/0/24.0
  Maximum labels: 3
Interface: ge-0/0/38.0
  Maximum labels: 3

me@5048> show system information
Model: acx5048
Family: junos
Junos: 17.4R2-S11
Hostname: 5048



-Aaron





_______________________________________________
juniper-nsp mailing list [email protected]
https://nam02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fpuck.nether.net%2Fmailman%2Flistinfo%2Fjuniper-nsp&amp;data=04%7C01%7Cgiuliano%40wztech.com.br%7Ca894125d52644bd4059a08d901135ff1%7C584787b077bd4312bf8815412b8ae504%7C1%7C0%7C637542005056277757%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&amp;sdata=nu9aYLCOw2BbA9LwXYzbH1oKczvLK7ZbqJ36Vi8ggrY%3D&amp;reserved=0

WZTECH is registered trademark of WZTECH NETWORKS.
Copyright © 2018 WZTECH NETWORKS. All Rights Reserved.

IMPORTANTE:
As informações deste e-mail e o conteúdo dos eventuais documentos anexos são 
confidenciais e para conhecimento exclusivo do destinatário. Se o leitor desta 
mensagem não for o seu destinatário, fica desde já notificado de que não poderá 
divulgar, distribuir ou, sob qualquer forma, dar conhecimento a terceiros das 
informações e do conteúdo dos documentos anexos. Neste caso, favor comunicar 
imediatamente o remetente, respondendo este e-mail ou telefonando ao mesmo, e 
em seguida apague-o.

CONFIDENTIALITY NOTICE:
The information transmitted in this email message and any attachments are 
solely for the intended recipient and may contain confidential or privileged 
information. If you are not the intended recipient, any review, transmission, 
dissemination or other use of this information is prohibited. If you have 
received this communication in error, please notify the sender immediately and 
delete the material from any computer, including any copies.

WZTECH is registered trademark of WZTECH NETWORKS.
Copyright © 2018 WZTECH NETWORKS. All Rights Reserved.

IMPORTANTE:
As informações deste e-mail e o conteúdo dos eventuais documentos anexos são 
confidenciais e para conhecimento exclusivo do destinatário. Se o leitor desta 
mensagem não for o seu destinatário, fica desde já notificado de que não poderá 
divulgar, distribuir ou, sob qualquer forma, dar conhecimento a terceiros das 
informações e do conteúdo dos documentos anexos. Neste caso, favor comunicar 
imediatamente o remetente, respondendo este e-mail ou telefonando ao mesmo, e 
em seguida apague-o.

CONFIDENTIALITY NOTICE:
The information transmitted in this email message and any attachments are 
solely for the intended recipient and may contain confidential or privileged 
information. If you are not the intended recipient, any review, transmission, 
dissemination or other use of this information is prohibited. If you have 
received this communication in error, please notify the sender immediately and 
delete the material from any computer, including any copies.
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to