devmadhuu commented on PR #12063:
URL: https://github.com/apache/ozone/pull/12063#issuecomment-7164851117

   > Should mis-replication correction also fall back from SSD to DISK when no 
suitable SSD target is available? This could improve replica placement, but it 
would also move a replica to a different storage tier.
   
   I'd keep `mis-replication` strict, with no fallback. A mis-replicated RATIS 
container already has all its replicas; only the rack spread is wrong. 
Decommission doesn't wait on it (DatanodeAdminMonitorImpl checks only 
under-replication), and the handler retries every cycle, so data is not at 
risk. A DISK fallback would copy to DISK, and then over-replication, which 
ignores storage type, may delete an SSD replica. Nothing moves it back to SSD 
later, so we'd trade a healthy SSD replica for a DISK one just to improve rack 
spread. Under-replication is different, because a replica is missing and 
decommission is blocked, which is why the fallback belongs there. It would help 
to log clearly, and maybe add a test, when mis-replication is skipped because 
no target of the container's tier exists.


-- 