Chung-En Lee created HDDS-17140:
-----------------------------------

             Summary:  S3 Gateway does not pick up the new OM version after ZDU 
finalization
                 Key: HDDS-17140
                 URL: https://issues.apache.org/jira/browse/HDDS-17140
             Project: Apache Ozone
          Issue Type: Bug
            Reporter: Chung-En Lee


The ZDU design doc ("Order of Operations During the Upgrade", step 5) says to 
rolling-restart S3 Gateway and other client processes on the new software 
before the cluster is finalized. At that point OM is still pre-finalized, so it 
reports the old version to clients.

S3 Gateway learns the OM version only once, when it handles its first request 
after starting, and keeps it for the life of the process. In a ZDU rolling 
restart S3 Gateway keeps serving traffic, so it captures the old version before 
finalization. After the admin finalizes the cluster, OM reports the new 
version, but S3 Gateway keeps the old one. Any new feature that depends on the 
finalized OM version stays disabled in S3 Gateway until it is restarted again.

Proposed fix (options):
1. Change the documented upgrade order so S3 Gateway is restarted after 
finalization.
2. Keep the current order, and document that S3 Gateway must be restarted again 
after finalization.
3. Make S3 Gateway aware OM version changes (e.g. after finalization) and 
re-initialize its OzoneClient automatically, so it picks up the latest OM 
version without a manual restart.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]

Reply via email to