https://issues.apache.org/jira/browse/IGNITE-8810?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16515535#comment-16515535
]
Jon Tricker edited comment on IGNITE-8810 at 6/18/18 9:52 AM:
--------------------------------------------------------------
Can be tested using the attached code (Unlocktest.java). Should NOT print the
error message at line 75.
was (Author: [email protected]):
Can be tested using the attached code. Should NOT print the error message at
line 75.
{code:java}
package igniteUnlockTest;
import org.apache.ignite.Ignition;
import org.apache.ignite.configuration.DataRegionConfiguration;
import org.apache.ignite.configuration.DataStorageConfiguration;
import org.apache.ignite.configuration.IgniteConfiguration;
import org.apache.ignite.spi.discovery.tcp.TcpDiscoverySpi;
import
org.apache.ignite.spi.discovery.tcp.ipfinder.multicast.TcpDiscoveryMulticastIpFinder;
import java.util.Arrays;
import java.util.List;
import org.apache.ignite.Ignite;
import org.apache.ignite.IgniteLock;
/**
* Test demonstrating the failure to unlock on ignite node exit. Creates a node
then second node which successfully joins the cluster. the
* second node then creates reentrant lock on a node, locks it and allows the
thread holding the lock to die. The node is closed as
* demonstrated by:
*
* Topology snapshot [ver=2, servers=2, clients=0, CPUs=4,
offheap=3.1GB, heap=0.5GB]
*
* changing to:
*
* Topology snapshot [ver=3, servers=1, clients=0, CPUs=4,
offheap=3.1GB, heap=0.5GB]
* Ignite node stopped OK [name=INSTANCE2, uptime=00:00:00.132]
*
* But when checked, on the remaining node, the lock is still held.
*
* Tested under Eclipse on Ignite 2.5.0. Problem seen on both RHL and Windows.
*/
public class UnlockTest
{
public final static String LOCKNAME="LOCKNAME";
public static void main( String[] args )
{
System.out.println( "Starting test" );
// Make a uniquely named ignite node.
IgniteConfiguration config1 = new DefaultIgniteConfig();
config1.setIgniteInstanceName("INSTANCE1");
// Start node. No caches required for this test.
Ignite node1 = Ignition.start(config1);
// Make a lock
IgniteLock lock = node1.reentrantLock(LOCKNAME, true, false, true);
// Check is initially unlocked
if (lock.isLocked()) {
System.out.println("Is initially locked");
}
// Create a remote thread.
TestThread thread = new TestThread(LOCKNAME);
// Run and exit thread. Will get a handle to the lock and lock it.
thread.start();
try {
// Wait for thread to close
thread.join();
// Ignite node should be closed now. But wait a while to be sure
Thread.sleep(5000);
}
catch (Exception e) {
System.out.println("Problem waiting for thread" +
e.getMessage());
}
// Check that the lock is unlocked
if (lock.isLocked()) {
// This should not be printed but it is.
System.out.println("ERROR ; Lock is not released on exit");
}
// Close node
node1.close();
System.out.println( "Test done" );
}
// Remote thread that takes a lock.
private static class TestThread extends Thread {
private Ignite node2;
private String lockName;
public TestThread(String lockName) {
// Remember lock name.
this.lockName = lockName;
// Start a new, uniquely named, ignite node for the thread,
IgniteConfiguration config2 = new DefaultIgniteConfig();
config2.setIgniteInstanceName("INSTANCE2");
// Start an ignite node. No caches required.
node2 = Ignition.start(config2);
}
public void run() {
// Get a handle to the lock and lock it.
// Note : failoverSafe=true. So it should release when the node
is closed.
IgniteLock lock = node2.reentrantLock(lockName, true, false, true);
lock.lock();
// Check that the lock is locked by this thread.
if (!lock.isLocked()) {
System.out.println("Is not locked");
}
if (!lock.isHeldByCurrentThread()){
System.out.println("Is held by worng thread");
}
// Should be able to run off the end, or crash, and get the
lock released,
// int i = 0;
// int a = 1/i;
// Even if we explicitly close the node the lock is still held.
node2.close();
}
}
// A simple, canned, ignite config.
private static class DefaultIgniteConfig extends IgniteConfiguration {
public DefaultIgniteConfig() {
// Some basic config.
setIgniteInstanceName("IGNITE_LOCK_TEST");
// Need a server to connect to. So be a server.
setClientMode(false);
setPeerClassLoadingEnabled(true);
// Set up node discovery
TcpDiscoverySpi discoSpi = new TcpDiscoverySpi();
TcpDiscoveryMulticastIpFinder finder = new
TcpDiscoveryMulticastIpFinder();
List<String> addresses =
Arrays.asList("127.0.0.1:47500..47502");
finder.setAddresses(addresses);
discoSpi.setIpFinder(finder);
setDiscoverySpi(discoSpi);
// Set up data storage
DataStorageConfiguration storeConfig = new
DataStorageConfiguration();
DataRegionConfiguration regionConfig =
storeConfig.getDefaultDataRegionConfiguration();
regionConfig.setName("IGNITE_LOCK_REGION");
// For locking should not need persistence.
regionConfig.setPersistenceEnabled(false);
setDataStorageConfiguration(storeConfig);
// Don't need any caches.
}
}
}
{code}
> Create failoverSafe for ReentrantLock
> -------------------------------------
>
> Key: IGNITE-8810
> URL: https://issues.apache.org/jira/browse/IGNITE-8810
> Project: Ignite
> Issue Type: Improvement
> Reporter: Evgenii Zhuravlev
> Priority: Major
> Attachments: UnlockTest.java
>
>
> Currently, it has the flag "failoverSafe", but it doesn't have any
> implementation for it
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)