https://issues.apache.org/jira/browse/IGNITE-29209?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=18139099#comment-18139099
]
Anton Vinogradov commented on IGNITE-29209:
-------------------------------------------
[Ignite PR Checker|https://ignite-pr-checker.is-a.dev/?pr=13751] verdict for PR
13751 · RunAll build [9473877|https://ci2.ignite.apache.org/build/9473877] ·
tested
[0d8a872|https://github.com/apache/ignite/pull/13751/commits/0d8a872f3551ce4172320ef218c4c43bdd33d04d]
· 149 suites ran, 0 reused
(/) *No blockers* — nothing in this run looks caused by this PR. 25 failing
tests are not blamed on this PR.
_What each label means and what to do: [verdict
glossary|https://github.com/anton-vinogradov/ignite-pr-checker/blob/main/docs/features.md#verdict-glossary]._
♻️ Settled after 1 auto re-run wave: #1 — 2 suites that failed mid-run.
> Allow SSL context factories to reload their context
> ---------------------------------------------------
>
> Key: IGNITE-29209
> URL: https://issues.apache.org/jira/browse/IGNITE-29209
> Project: Ignite
> Issue Type: Sub-task
> Reporter: Anton Vinogradov
> Assignee: Anton Vinogradov
> Priority: Major
> Labels: ise
> Time Spent: 5h 20m
> Remaining Estimate: 0h
>
> A subclass of {{AbstractSslContextFactory}} can call the protected {{init()}}
> method to pick up updated TLS settings and stores before a node restarts with
> the same factory instance. If loading succeeds, the base {{create()}} returns
> the new context. If it fails, the previous context stays cached.
> h3. Compatibility
> {{init()}} is final. If your subclass already declares a no-argument
> {{init()}} method, rename it and recompile the subclass before upgrading. A
> subclass built against an earlier release may fail to load.
> [PR #13751|https://github.com/apache/ignite/pull/13751]
--
This message was sent by Atlassian Jira