https://issues.apache.org/jira/browse/IGNITE-17048?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=18031090#comment-18031090
]
Aleksandr Polovtsev commented on IGNITE-17048:
----------------------------------------------
Closing the issue as it has not been reproduced in a while
> Some failing tests make other tests fail too
> --------------------------------------------
>
> Key: IGNITE-17048
> URL: https://issues.apache.org/jira/browse/IGNITE-17048
> Project: Ignite
> Issue Type: Bug
> Reporter: Aleksandr Polovtsev
> Priority: Major
> Labels: ignite-3
> Fix For: 3.2
>
>
> Looks like after some tests fail, they do not correctly free the used ports,
> because other tests start to fail with a "Failed to start the connection
> manager: No available port in range [3346-3346]" message.
> This error occurs due to previous test failing to stop a node with
> AssertionError "Raft groups are still running
> [602f614c-9d19-4467-bcdf-d248d9e3a410_part_1,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_0,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_6,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_4,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_3,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_8,
> 602f614c-9d19-4467-bcdf-d248d9e3a410_part_7]"
> Example of a failed build:
> https://ci.ignite.apache.org/buildConfiguration/ignite3_Test_RunAllTests/6583070
> A possible solution might be to create a diagnostics tool that will print the
> name of the process that occupies the blocked port.
--
This message was sent by Atlassian Jira
(v8.20.10#820010)