https://issues.apache.org/jira/browse/IGNITE-17985?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17728775#comment-17728775
 ] 

Jeremy McMillan commented on IGNITE-17985:
------------------------------------------

Matching GitHub issue 
[#10648|[http://example.com|https://github.com/apache/ignite/issues/10648]] has 
additional information.

> intermittent failure: long pathname prevents server node start on Windows 11 
> with working IPv6 network
> ------------------------------------------------------------------------------------------------------
>
>                 Key: IGNITE-17985
>                 URL: https://issues.apache.org/jira/browse/IGNITE-17985
>             Project: Ignite
>          Issue Type: Bug
>    Affects Versions: 2.14
>         Environment: Windows 11
> OpenJDK 17
> Apache Ignite 2.14
>            Reporter: Jeremy McMillan
>            Priority: Critical
>
> Depending on the IP addresses assigned to nodes before startup, Ignite 
> default behavior constructs a consistent ID from a tuple of IP addresses and 
> ports identifying the node, which will result in a failure to create local 
> page cache folder using the consistent ID as a pathname, 
> non-deterministically preventing node startup.
> example log message:
> {{[08:52:17] Ignite node stopped wih ERRORS [uptime=00:00:02.143]}}
> {{class org.apache.ignite.IgniteException: Failed to start processor: 
> GridProcessorAdapter []}}
> {{        at 
> org.apache.ignite.internal.util.IgniteUtils.convertException(IgniteUtils.java:1145)}}
> {{        at org.apache.ignite.Ignition.start(Ignition.java:356)}}
> {{        at 
> org.apache.ignite.startup.cmdline.CommandLineStartup.main(CommandLineStartup.java:365)}}
> {{Caused by: class org.apache.ignite.IgniteCheckedException: Failed to start 
> processor: GridProcessorAdapter []}}
> {{        at 
> org.apache.ignite.internal.IgniteKernal.startProcessor(IgniteKernal.java:1787)}}
> {{        at 
> org.apache.ignite.internal.IgniteKernal.start(IgniteKernal.java:1066)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance.start0(IgnitionEx.java:1757)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance.start(IgnitionEx.java:1679)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.start0(IgnitionEx.java:1121)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.startConfigurations(IgnitionEx.java:1015)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.start(IgnitionEx.java:921)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.start(IgnitionEx.java:840)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.start(IgnitionEx.java:710)}}
> {{        at 
> org.apache.ignite.internal.IgnitionEx.start(IgnitionEx.java:679)}}
> {{        at org.apache.ignite.Ignition.start(Ignition.java:353)}}
> {{        ... 1 more}}
> {{Caused by: class org.apache.ignite.IgniteCheckedException: Failed to create 
> page store work directory: 
> C:\Users\jt\AppData\Local\IgniteCluster\node0\db\0_0_0_0_0_0_0_1_10_0_1_84_127_0_0_1_2600_1700_5650_3cff_481f_54f_adb9_437_2600_1700_5650_3cff_8188_5e65_f1fc_237_2600_1700_5650_3cff_84a4_9fdf_feb2_b01f_2600_1700_5650_3cff_9194_cd0d_813f_2e71_2600_1700_5650_3cff_a042_5e6f_9b0b_492b_2600_1700_5650_3cff_bcc4_3dca_bcd5_41cb_47500}}
> {{        at 
> org.apache.ignite.internal.util.IgniteUtils.ensureDirectory(IgniteUtils.java:9971)}}
> {{        at 
> org.apache.ignite.internal.processors.cache.GridLocalConfigManager.<init>(GridLocalConfigManager.java:127)}}
> {{        at 
> org.apache.ignite.internal.processors.cache.GridCacheProcessor.start(GridCacheProcessor.java:618)}}
> {{        at 
> org.apache.ignite.internal.IgniteKernal.startProcessor(IgniteKernal.java:1784)}}
> {{        ... 11 more}}
> {{Failed to start grid: Failed to start processor: GridProcessorAdapter []}}
> Bad workaround: reboot the node. With good luck, the IP addresses will 
> normalize to a shorter string, and the node will start. With bad luck, the IP 
> addresses will be too long: try again.
> Acceptable workaround: override the nodes' consistent IDs by [setting the 
> property or environment 
> variable|https://ignite.apache.org/releases/latest/javadoc/org/apache/ignite/IgniteSystemProperties.html#IGNITE_OVERRIDE_CONSISTENT_ID]
>  at startup time to an appropriate value.
> Factors:
>  * #IGNITE-9995
>  * #IGNITE-2416



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to