https://issues.apache.org/jira/browse/IGNITE-1572?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14952943#comment-14952943
 ] 

Pavel  Tupitsyn commented on IGNITE-1572:
-----------------------------------------

1) I have fixed TestPortableObjectInTask by adding a wrapper in the test 
itself. This use is very unlikely, so we can tell users to create their own 
wrapper (which is trivial).
2) .

> .Net: Check if we can get rid of "WritePortableOrSerializable" method.
> ----------------------------------------------------------------------
>
>                 Key: IGNITE-1572
>                 URL: https://issues.apache.org/jira/browse/IGNITE-1572
>             Project: Ignite
>          Issue Type: Task
>          Components: interop
>    Affects Versions: ignite-1.4
>            Reporter: Vladimir Ozerov
>            Assignee: Pavel  Tupitsyn
>            Priority: Critical
>             Fix For: 1.5
>
>
> We have lots of places where "WritePortableOrSerializable" routine is 
> invoked. It is not clear why do we need it provided that we already handle 
> [Serializable] classes properly. 
> Looks like we are able to get rid of it safely, aren't we? Need to 
> double-check.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to