https://issues.apache.org/jira/browse/HIVE-17843?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16358900#comment-16358900
 ] 

Vihang Karajgaonkar commented on HIVE-17843:
--------------------------------------------

[~zi] Can you give a example query which can lead to incorrect results? Thanks 
for reporting this..

> UINT32 Parquet columns are handled as signed INT32-s, silently reading 
> incorrect data
> -------------------------------------------------------------------------------------
>
>                 Key: HIVE-17843
>                 URL: https://issues.apache.org/jira/browse/HIVE-17843
>             Project: Hive
>          Issue Type: Bug
>            Reporter: Zoltan Ivanfi
>            Priority: Major
>
> An unsigned 32 bit Parquet column, such as
> {noformat}
> optional int32 uint_32_col (UINT_32)
> {noformat}
> is read by Hive as if it were signed, leading to incorrect results.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to