https://issues.apache.org/jira/browse/FLINK-5658?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15944706#comment-15944706
 ] 

ASF GitHub Bot commented on FLINK-5658:
---------------------------------------

Github user fhueske commented on a diff in the pull request:

    https://github.com/apache/flink/pull/3386#discussion_r108352888
  
    --- Diff: 
flink-libraries/flink-table/src/main/scala/org/apache/flink/table/plan/nodes/datastream/DataStreamOverAggregate.scala
 ---
    @@ -112,7 +113,12 @@ class DataStreamOverAggregate(
                   "condition.")
             }
           case _: RowTimeType =>
    -        throw new TableException("OVER Window of the EventTime type is not 
currently supported.")
    +        if (overWindow.lowerBound.isUnbounded && 
overWindow.upperBound.isCurrentRow) {
    +          createUnboundedAndCurrentRowEventTimeOverWindow(inputDS)
    --- End diff --
    
    Updated JIRA 
[FLINK-5658](https://issues.apache.org/jira/browse/FLINK-5658). 
@sunjincheng121, not sure if that was an issue with your permissions. It is not 
possible to modify a closed issue. You need to reopen it first.


> Add event time OVER ROWS BETWEEN UNBOUNDED PRECEDING aggregation to SQL
> -----------------------------------------------------------------------
>
>                 Key: FLINK-5658
>                 URL: https://issues.apache.org/jira/browse/FLINK-5658
>             Project: Flink
>          Issue Type: Sub-task
>          Components: Table API & SQL
>            Reporter: Fabian Hueske
>            Assignee: hongyuhong
>             Fix For: 1.3.0
>
>
> The goal of this issue is to add support for OVER RANGE aggregations on event 
> time streams to the SQL interface.
> Queries similar to the following should be supported:
> {code}
> SELECT 
>   a, 
>   SUM(b) OVER (PARTITION BY c ORDER BY rowTime() ROWS BETWEEN UNBOUNDED 
> PRECEDING AND CURRENT ROW) AS sumB,
>   MIN(b) OVER (PARTITION BY c ORDER BY rowTime() ROWS BETWEEN UNBOUNDED 
> PRECEDING AND CURRENT ROW) AS minB
> FROM myStream
> {code}
> The following restrictions should initially apply:
> - All OVER clauses in the same SELECT clause must be exactly the same.
> - The PARTITION BY clause is optional (no partitioning results in single 
> threaded execution).
> - The ORDER BY clause may only have rowTime() as parameter. rowTime() is a 
> parameterless scalar function that just indicates processing time mode.
> - bounded PRECEDING is not supported (see FLINK-5655)
> - FOLLOWING is not supported.
> The restrictions will be resolved in follow up issues. If we find that some 
> of the restrictions are trivial to address, we can add the functionality in 
> this issue as well.
> An event-time OVER ROWS window will not be able to handle late data, because 
> this would mean in insert a row into a sorted order shift all other 
> computations. This would be too expensive to maintain. Therefore, we will 
> throw an error if a user tries to use an event-time OVER ROWS window with 
> late data handling.
> This issue includes:
> - Design of the DataStream operator to compute OVER ROW aggregates
> - Translation from Calcite's RelNode representation (LogicalProject with 
> RexOver expression).



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to