Purushottam Sinha created FLINK-41608:
-----------------------------------------

             Summary: [tests] UdfE2eITCase (java, batch) fails intermittently: 
the job ends seconds after it starts and the test times out waiting for its 
output
                 Key: FLINK-41608
                 URL: https://issues.apache.org/jira/browse/FLINK-41608
             Project: Flink
          Issue Type: Bug
          Components: Flink CDC
    Affects Versions: cdc-3.8.0
            Reporter: Purushottam Sinha


h3. Problem
{{UdfE2eITCase}} ({{flink-cdc-pipeline-e2e-tests}}, stage1) fails 
intermittently in its first variant (language: java, batchMode: true), in both 
{{testFlinkCompatibleScalarFunctions}} and {{testUserDefinedFunctions}}, on 
Flink 1.20.3 and 2.2.0:
{noformat}
java.util.concurrent.TimeoutException:
failed to get specific event: 
CreateTableEvent{tableId=transform_test_1vk5wus.TABLEALPHA, ...} from stdout: 
Starting Task Manager ...
    at 
PipelineTestEnvironment.waitUntilSpecificEvent(PipelineTestEnvironment.java:632)
{noformat}
Between 2026-09-21 and 2026-11-19 it failed 9 times on apache/flink-cdc, 5 of 
them on master:
||Date||Build||Flink||Test||
|2026-09-21|[master 
push|https://github.com/apache/flink-cdc/actions/runs/35582084703]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-09-22|[PR, 
FLINK-39410|https://github.com/apache/flink-cdc/actions/runs/35709139302]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-09-22|[PR, 
FLINK-40552|https://github.com/apache/flink-cdc/actions/runs/35713792031]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-09-29|[master 
push|https://github.com/apache/flink-cdc/actions/runs/36509888510]|1.20.3|testUserDefinedFunctions[1]|
|2026-10-20|[master 
nightly|https://github.com/apache/flink-cdc/actions/runs/39351812063]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-10-21|[master 
push|https://github.com/apache/flink-cdc/actions/runs/39577186792]|2.2.0|testUserDefinedFunctions[1]|
|2026-10-26|[master 
nightly|https://github.com/apache/flink-cdc/actions/runs/40253175676]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-11-11|[PR, 
FLINK-41313|https://github.com/apache/flink-cdc/actions/runs/42974467738]|2.2.0|testFlinkCompatibleScalarFunctions[1]|
|2026-11-19|[PR, 
FLINK-41570|https://github.com/apache/flink-cdc/actions/runs/44588678068]|2.2.0|testFlinkCompatibleScalarFunctions[1]|

h3. What the logs show
The test output holds only the TaskManager log. From [the 2026-11-19 
failure|https://github.com/apache/flink-cdc/actions/runs/44588678068/job/136122109366]:
* 06:40:30.28: the batch job's 4 source subtasks ({{Source: Flink CDC Event 
Source: mysql -> ... -> BatchPrePartition}}) start.
* 06:40:31.27: subtasks 2/4 and 4/4 get no split and finish.
* Subtasks 1/4 and 3/4 read the snapshot splits of TABLEBETA and TABLEALPHA (4 
rows each) and finish at 06:40:33.63.
* The JobManager rejects the FINISHED report of subtask 1/4, and the 
TaskManager releases the job at 06:40:33.89:
{noformat}
org.apache.flink.runtime.jobmaster.ExecutionGraphException: The execution 
attempt d10ba58f3a855405535af6d6d7caf886_cbc357ccb763df2852fee8c4fc7d55f2_0_0 
was not found.
{noformat}
* Nothing reaches the values sink. The test keeps polling the TaskManager 
output for {{EVENT_WAITING_TIMEOUT}} (3 minutes) and fails with the timeout 
above.

All 9 failures show the same thing: all 4 source subtasks reach FINISHED, and 
the JobManager answers one of them with "execution attempt ... was not found". 
The job has already ended on the JobManager, and why is not in the test output: 
{{PipelineTestEnvironment#waitUntilSpecificEvent}} does not check the job's 
status, and its timeout message prints only the TaskManager output, although 
the JobManager log is captured in {{jobManagerConsumer}}.

h3. Proposed fix
# In {{waitUntilSpecificEvent}}, check the job's status on each poll and fail 
at once if the job is FAILED or CANCELED, with the job's root exception; on a 
timeout, add the JobManager log to the message. This also makes other tests 
that fail with this timeout diagnosable.
# With the JobManager's exception from the next failure, fix the cause.

h3. Related
* FLINK-37641: the same timeout in {{SchemaEvolveE2eITCase}} (open).
* FLINK-38540: an earlier {{UdfE2eITCase}} failure with a different cause 
(concurrent modification while compiling expressions), fixed in cdc-3.6.0.
* In the same period, 
{{ValuesE2eITCase.testValuesSingleSplitSingleTable(WithDefaultValue)}} failed 7 
times and {{MysqlE2eITCase.testSyncWholeDatabaseInBatchMode}} 3 times with the 
same timeout; whether they have the same cause was not checked.



--
This message was sent by Atlassian Jira
(v10.3.26#10030026)

Reply via email to