Martijn Visser created FLINK-40648:
--------------------------------------

             Summary: PrometheusReporter drops all metrics of a process when 
two metric group variables sanitise to the same label name
                 Key: FLINK-40648
                 URL: https://issues.apache.org/jira/browse/FLINK-40648
             Project: Flink
          Issue Type: Bug
          Components: Runtime / Metrics
    Affects Versions: 1.20.5, 2.2.1, 2.3.0, 2.4.0
            Reporter: Martijn Visser


AbstractPrometheusReporter.notifyOfAddedMetric builds the Prometheus label 
names by filtering every metric group variable through [^a-zA-Z0-9:_] -> _ and 
adding each result to dimensionKeys, without checking whether two keys produced 
the same name.

metricGroup.addGroup("a.b", "v1").addGroup("a-b", "v2") gives the variables 
<a.b> and <a-b>, both of which filter to a_b, and the scrape then carries

{code}
flink_scope_dup{a_b="v1",a_b="v2",} 7.0
{code}

Prometheus 3.11.2 scraping that body:

{code}
health   = down
lastError= label name "a_b" is not unique: invalid sample
{code}

The rejection is in tsdb/head_append.go, and scrape.go has no case for 
ErrInvalidSample, so it breaks out of the sample loop. The scrape is abandoned 
rather than the one sample skipped, which means every other metric from that 
TaskManager or JobManager is lost too and the target goes down. Verified with a 
body holding the colliding metric plus one valid metric: both come back empty 
and up is 0.

Only a user-supplied addGroup key can trigger this. Flink's own variables are 
all [a-z0-9_] already.

Two metrics named a.b and a-b in one group collide the same way one level up. 
There the second metric reuses the first one's collector, so the series shows 
whichever registered last under the first one's help string. That is the same 
defect FLINK-32649 reports, since collectorsWithCountByMetricName is keyed on 
the scoped name without the label names.



--