https://issues.apache.org/jira/browse/FLINK-5532?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15834177#comment-15834177
 ] 

ASF GitHub Bot commented on FLINK-5532:
---------------------------------------

Github user StephanEwen commented on a diff in the pull request:

    https://github.com/apache/flink/pull/3180#discussion_r97283937
  
    --- Diff: 
flink-streaming-java/src/main/java/org/apache/flink/streaming/api/windowing/assigners/SlidingAlignedProcessingTimeWindows.java
 ---
    @@ -35,7 +35,7 @@
      * <p>
      * <b>WARNING:</b> Bear in mind that no rescaling and no backwards 
compatibility is supported.
      * */
    -public class SlidingAlignedProcessingTimeWindows extends 
BaseAlignedWindowAssigner {
    +public final class SlidingAlignedProcessingTimeWindows extends 
BaseAlignedWindowAssigner {
    --- End diff --
    
    Yes, they should be `@PublicEvolving`.
    Will add that when merging...



> Make the marker WindowAssigners for the fast aligned windows non-extendable.
> ----------------------------------------------------------------------------
>
>                 Key: FLINK-5532
>                 URL: https://issues.apache.org/jira/browse/FLINK-5532
>             Project: Flink
>          Issue Type: Bug
>          Components: Windowing Operators
>    Affects Versions: 1.2.0
>            Reporter: Kostas Kloudas
>            Assignee: Kostas Kloudas
>             Fix For: 1.2.0
>
>
> This issue refers to the {{SlidingAlignedProcessingTimeWindows}} and 
> {{TumblingAlignedProcessingTimeWindows}} and proposes to:
> (1) make the classes {{final}}
> (2) use {{getClass()}} for the check, not {{instanceof()}}



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)