[ https://issues.apache.org/jira/browse/FLINK-30239?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Lijie Wang reassigned FLINK-30239: ---------------------------------- Assignee: Rui Fan (was: Lijie Wang) > The flame graph doesn't work due to groupExecutionsByLocation has bug > --------------------------------------------------------------------- > > Key: FLINK-30239 > URL: https://issues.apache.org/jira/browse/FLINK-30239 > Project: Flink > Issue Type: Bug > Components: Runtime / REST, Runtime / Web Frontend > Affects Versions: 1.16.0, 1.17.0 > Reporter: Rui Fan > Assignee: Rui Fan > Priority: Major > Labels: pull-request-available > Fix For: 1.17.0, 1.16.1 > > Attachments: image-2022-11-30-00-10-48-940.png, > image-2022-11-30-00-11-09-728.png, image-2022-11-30-00-14-11-355.png > > > The flame graph cannot be generated forever when multiple tasks in the same > TM. It's caused by FLINK-26074 > > h1. Root cause: > A Set cannot be converted to an ImmutableSet during the aggregation of > ExecutionAttemptIDs. It will cause only the first ExecutionAttemptID of the > TM to be added to the set, the second ExecutionAttemptID will fail. > > !image-2022-11-30-00-14-11-355.png! > > > > !image-2022-11-30-00-11-09-728.png! > > Exception Info: > !image-2022-11-30-00-10-48-940.png! -- This message was sent by Atlassian Jira (v8.20.10#820010)