https://issues.apache.org/jira/browse/FLINK-12458?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

zhijiang updated FLINK-12458:
-----------------------------
    Description: If the consumer can not establish a connection to remote task 
executor, which might indicate the remote task executor is not reachable. We 
could wrap this connection exception into new proposed 
`PartitionConnectionException` which also extends `PartitionException`, then 
the job master would decide whether to restart the upstream region to 
re-producer partition data.  (was: If the consumer can not establish a 
connection to remote task executor, which might indicate the remote task 
executor is not reachable. We could wrap this connection exception into 
existing `PartitionNotFoundException`, then the job master would decide whether 
to restart the upstream region to re-producer partition data.)

> Introduce PartitionConnectionException for unreachable producer
> ---------------------------------------------------------------
>
>                 Key: FLINK-12458
>                 URL: https://issues.apache.org/jira/browse/FLINK-12458
>             Project: Flink
>          Issue Type: Sub-task
>          Components: Runtime / Network
>            Reporter: zhijiang
>            Assignee: zhijiang
>            Priority: Minor
>
> If the consumer can not establish a connection to remote task executor, which 
> might indicate the remote task executor is not reachable. We could wrap this 
> connection exception into new proposed `PartitionConnectionException` which 
> also extends `PartitionException`, then the job master would decide whether 
> to restart the upstream region to re-producer partition data.



--
This message was sent by Atlassian JIRA