https://issues.apache.org/jira/browse/FLINK-11084?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tzu-Li (Gordon) Tai updated FLINK-11084:
----------------------------------------
    Fix Version/s:     (was: 1.6.3)
                   1.6.4

> Incorrect ouput after two consecutive split and select
> ------------------------------------------------------
>
>                 Key: FLINK-11084
>                 URL: https://issues.apache.org/jira/browse/FLINK-11084
>             Project: Flink
>          Issue Type: Bug
>          Components: Streaming
>            Reporter: Shimin Yang
>            Assignee: Shimin Yang
>            Priority: Critical
>              Labels: pull-request-available
>             Fix For: 1.5.6, 1.6.4, 1.7.2, 1.8.0
>
>
> The second OutputSelector of two successive split and select are actually not 
> rely on the first one. They are in the same array of OutputSelector in 
> DirectedOutput.
> For example.
> outputSelector1 => \{“name1” or ”name2“}
> outputSelector2 => \{”name3“ or “name4”}
> resultStream = 
> dataStream.split(outputSelector1).select("name2").split(outputSelector2).select("name3")
> expectedResult for input \{StreamRecord1}:
> outputSelector1 => \{”name1“}
> outputSelector2 => \{”name3“}
> resultStream => {}
> actualResult:
> resultStream => \{StreamRecord1}



--