Gary Yao created FLINK-10663: -------------------------------- Summary: Closing StreamingFileSink can cause NPE Key: FLINK-10663 URL: https://issues.apache.org/jira/browse/FLINK-10663 Project: Flink Issue Type: Bug Components: filesystem-connector, Streaming Connectors Affects Versions: 1.6.1, 1.7.0 Environment: Rev cb141940821bcf62f4102dfd5c76aff99d0c15d1 Reporter: Gary Yao
*Description* If the sink is closed before it's state is initialized, an NPE is thrown. *Stacktrace* {code} java.lang.NullPointerException at org.apache.flink.streaming.api.functions.sink.filesystem.StreamingFileSink.close(StreamingFileSink.java:378) at org.apache.flink.api.common.functions.util.FunctionUtils.closeFunction(FunctionUtils.java:43) at org.apache.flink.streaming.api.operators.AbstractUdfStreamOperator.dispose(AbstractUdfStreamOperator.java:117) at org.apache.flink.streaming.runtime.tasks.StreamTask.disposeAllOperators(StreamTask.java:477) at org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:378) at org.apache.flink.runtime.taskmanager.Task.run(Task.java:704) at java.lang.Thread.run(Thread.java:748) {code} -- This message was sent by Atlassian JIRA (v7.6.3#76005)