Don’t really have an answer, other than a google search on " IDC3009i RC 30 RSN 
62 IGG0CLF8".  Not sure if this helps or not.

Question & Answer

Question
Catalog Access Error when attempting to define 3494. After defining the tape 
library using the ISMF panels, when trying to EXIT using PF3, a 'Catalog Access 
errror' is encountered with the message IDC3009i RC 30 RSN 62 IGG0CLF8

Answer
PROBLEM

Catalog Access Error received when attempting to define D/T3494. After defining 
the tape library using the ISMF panels, when trying to EXIT using PF3, a 
'Catalog Access errror' is encountered msgIDC3009i RC30 RSN62 IGG0CLF8

Customer has set the 'UCAT' parameter in col. 64 of LOADxx to indicate the 
high-level qualifier (HLQ) they are using for the 'GENERAL' catalog and IPL'ed 
the system. Next, the TCDB was created with HLQ 'UCAT'.

The command F CATALOG,REPORT was issued and shows SYS1 as the HLQ. When trying 
to define the library via ISMF, customer is receiving msgIDC3009I RC30 RSN62.

RESOLUTION

The customer was doing a manual IPL, as opposed to an automatic IPL, and this 
defaulted to the SYSCATxx member in SYS1.NUCLEUS. This member did not have a 
tape volume HLQ name defined. The SYSCATxx member in the nucleus has a 
different format than the LOADxx member. The DFSMS Managing Catalogs manual 
shows the formats. In the LOADxx the TAPEVOL HLQ is in column 64, in the 
SYSCATxx in the nucleus it is in column 55.
_____________________________________________________________________________________________________
Dave Jousma
AVP | Manager, Systems Engineering  

Fifth Third Bank  |  1830 East Paris Ave, SE  |  MD RSCB2H  |  Grand Rapids, MI 
49546
616.653.8429  |  fax: 616.653.2717



-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Mark Pace
Sent: Friday, September 6, 2019 11:35 AM
To: [email protected]
Subject: Re: Recreate a VOLCAT

**CAUTION EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

Ran an EXAMINE and that looks okay.
IDC01700I INDEXTEST BEGINS

IDC11773I              14 KEYS PROCESSED ON INDEX LEVEL   1, AVERAGE KEY
LENGTH:     2.0
IDC11774I CURRENT INDEX CISIZE IS  1024, RECOMMENDED MINIMUM INDEX CISIZE IS  
1024 IDC01724I INDEXTEST COMPLETE - NO ERRORS DETECTED

IDC01701I DATATEST BEGINS

IDC01709I DATATEST COMPLETE - NO ERRORS DETECTED

IDC01708I 14 CONTROL INTERVALS ENCOUNTERED

IDC01710I DATA COMPONENT CONTAINS 507 RECORDS

IDC01711I DATA COMPONENT CONTAINS 0 DELETED CONTROL INTERVALS

IDC01712I MAXIMUM LENGTH DATA RECORD CONTAINS 2289 BYTES

IDC01722I 98 PERCENT FREE SPACE

IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0


On Fri, Sep 6, 2019 at 11:22 AM Mark Pace <[email protected]> wrote:

> I have some problem with my SYS1.VOLCAT.VGENERAL and appears I need to 
> recreate it.
> IDC3014I CATALOG ERROR
> IDC3009I ** VSAM CATALOG RETURN CODE IS 30 - REASON CODE IS 
> IGG0CLF8-62 IDC1566I ** SUPPRESSED ENTRY NOT LISTED
>
> Is there a procedure recreating a VOLCAT?
>
> --
> The postings on this site are my own and don’t necessarily represent 
> Mainline’s positions or opinions
>
> Mark D Pace
> Senior Systems Engineer
> Mainline Information Systems
>
>
>
>

--
The postings on this site are my own and don’t necessarily represent Mainline’s 
positions or opinions

Mark D Pace
Senior Systems Engineer
Mainline Information Systems

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN **CAUTION EXTERNAL 
EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to