Don’t really have an answer, other than a google search on " IDC3009i RC 30 RSN 62 IGG0CLF8". Not sure if this helps or not.
Question & Answer Question Catalog Access Error when attempting to define 3494. After defining the tape library using the ISMF panels, when trying to EXIT using PF3, a 'Catalog Access errror' is encountered with the message IDC3009i RC 30 RSN 62 IGG0CLF8 Answer PROBLEM Catalog Access Error received when attempting to define D/T3494. After defining the tape library using the ISMF panels, when trying to EXIT using PF3, a 'Catalog Access errror' is encountered msgIDC3009i RC30 RSN62 IGG0CLF8 Customer has set the 'UCAT' parameter in col. 64 of LOADxx to indicate the high-level qualifier (HLQ) they are using for the 'GENERAL' catalog and IPL'ed the system. Next, the TCDB was created with HLQ 'UCAT'. The command F CATALOG,REPORT was issued and shows SYS1 as the HLQ. When trying to define the library via ISMF, customer is receiving msgIDC3009I RC30 RSN62. RESOLUTION The customer was doing a manual IPL, as opposed to an automatic IPL, and this defaulted to the SYSCATxx member in SYS1.NUCLEUS. This member did not have a tape volume HLQ name defined. The SYSCATxx member in the nucleus has a different format than the LOADxx member. The DFSMS Managing Catalogs manual shows the formats. In the LOADxx the TAPEVOL HLQ is in column 64, in the SYSCATxx in the nucleus it is in column 55. _____________________________________________________________________________________________________ Dave Jousma AVP | Manager, Systems Engineering Fifth Third Bank | 1830 East Paris Ave, SE | MD RSCB2H | Grand Rapids, MI 49546 616.653.8429 | fax: 616.653.2717 -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Mark Pace Sent: Friday, September 6, 2019 11:35 AM To: [email protected] Subject: Re: Recreate a VOLCAT **CAUTION EXTERNAL EMAIL** **DO NOT open attachments or click on links from unknown senders or unexpected emails** Ran an EXAMINE and that looks okay. IDC01700I INDEXTEST BEGINS IDC11773I 14 KEYS PROCESSED ON INDEX LEVEL 1, AVERAGE KEY LENGTH: 2.0 IDC11774I CURRENT INDEX CISIZE IS 1024, RECOMMENDED MINIMUM INDEX CISIZE IS 1024 IDC01724I INDEXTEST COMPLETE - NO ERRORS DETECTED IDC01701I DATATEST BEGINS IDC01709I DATATEST COMPLETE - NO ERRORS DETECTED IDC01708I 14 CONTROL INTERVALS ENCOUNTERED IDC01710I DATA COMPONENT CONTAINS 507 RECORDS IDC01711I DATA COMPONENT CONTAINS 0 DELETED CONTROL INTERVALS IDC01712I MAXIMUM LENGTH DATA RECORD CONTAINS 2289 BYTES IDC01722I 98 PERCENT FREE SPACE IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0 On Fri, Sep 6, 2019 at 11:22 AM Mark Pace <[email protected]> wrote: > I have some problem with my SYS1.VOLCAT.VGENERAL and appears I need to > recreate it. > IDC3014I CATALOG ERROR > IDC3009I ** VSAM CATALOG RETURN CODE IS 30 - REASON CODE IS > IGG0CLF8-62 IDC1566I ** SUPPRESSED ENTRY NOT LISTED > > Is there a procedure recreating a VOLCAT? > > -- > The postings on this site are my own and don’t necessarily represent > Mainline’s positions or opinions > > Mark D Pace > Senior Systems Engineer > Mainline Information Systems > > > > -- The postings on this site are my own and don’t necessarily represent Mainline’s positions or opinions Mark D Pace Senior Systems Engineer Mainline Information Systems ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN **CAUTION EXTERNAL EMAIL** **DO NOT open attachments or click on links from unknown senders or unexpected emails** This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN