Hello,
I installed the USI VTA to our customer. The tape drives are attached by a
single shared channel path.
I know BARR ESCON channel's EMIF dose not support, so those tape drives can
only be onlined in one LPAR at one point.
I tried path online with one LPAR (MIF ID:3 partition), but the channel path
issued PATH NOT VALIDATED.
Why was this message issued? If there is a solutions, could you please
advice.
CF CHP(50),ON
IEE754I NOT ALL PATHS BROUGHT ONLINE WITH CHP(50)
IEE502I CHP(50),ONLINE
IEE712I CONFIG PROCESSING COMPLETE
D M=CHP(50)
CHPID 50: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE
DEVICE STATUS FOR CHANNEL PATH 50
0 1 2 3 4 5 6 7 8 9 A B C D E F
0A60 \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@ \@
SWITCH DEVICE NUMBER = NONE
PHYSICAL CHANNEL ID = 01E0
************************ SYMBOL EXPLANATIONS ************************
+ ONLINE @ PATH NOT VALIDATED - OFFLINE . DOES NOT EXIST
* PHYSICALLY ONLINE \ PATH NOT OPERATIONAL
CF CHP(50),ON
IEE712I CONFIG PROCESSING COMPLETE
D M=CHP(50)
CHPID 50: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE
DEVICE STATUS FOR CHANNEL PATH 50
0 1 2 3 4 5 6 7 8 9 A B C D E F
0A60 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
SWITCH DEVICE NUMBER = NONE
PHYSICAL CHANNEL ID = 01E0
************************ SYMBOL EXPLANATIONS ************************
+ ONLINE @ PATH NOT VALIDATED - OFFLINE . DOES NOT EXIST
* PHYSICALLY ONLINE \ PATH NOT OPERATIONAL
IOCP DECK:
CHPID PATH=(CSS(0),50),SHARED, X
PARTITION=((SYSB,SYSC,SYSV),(=)),PCHID=1E0,TYPE=CNC
CNTLUNIT CUNUMBR=A600,PATH=((CSS(0),50)), X
UNITADD=((00,016)),UNIT=3490
IODEVICE ADDRESS=(A600,016),CUNUMBR=(A600),STADET=Y,UNIT=3490
Thanks in advance.
Best regards,
Toyokazu Kobayashi
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN