I've lost track of the original problem description, especially the motivation for this effort. The easiest way to encompass all of the sysmods belonging to an FMID is "FORFMID()". This would cover the PTFs. The SMP/E message says this.
"The indicated SYSMOD has already been applied or accepted, so you must determine if you need to apply or accept the SYSMOD again. In most cases you should not apply or accept the SYSMOD again, therefore, remove the SYSMOD from the SELECT list and rerun the job. If you do want to apply or accept the SYSMOD again, add the REDO operand and rerun the job." So, why do you want to re-APPLY the base sysmod? . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Jake Anderson Sent: Thursday, March 07, 2019 10:22 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: SMP/e REDO FMID clarification GEXT was already specified Actually I am doing REDO of base and just APPLY on top of already applied FMID fails with the message ID : GIM50202E On Thu, 7 Mar, 2019, 10:17 PM Jousma, David, < 000001a0403c5dc1-dmarc-requ...@listserv.ua.edu> wrote: > If it were me, I'd apply the base FMID by itself, and accept it, then > apply the PTF's on top of that, and only accept those after all > testing is completed, or just prior to next round of IPL's. > > The problem with applying all at once, is that you have nothing to > fall back on with SMPE restore. > > _________________________________________________________________ > Dave Jousma > Mainframe Engineering, Assistant Vice President david.jou...@53.com > 1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f > 616.653.2717 > > -----Original Message----- > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On > Behalf Of Jake Anderson > Sent: Thursday, March 7, 2019 1:09 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: SMP/e REDO FMID clarification > > **CAUTION EXTERNAL EMAIL** > > **DO NOT open attachments or click on links from unknown senders or > unexpected emails** > > Hi > > I am in process of reapplying a a product base FMID with SMPE control > card Keyword REDO. I understand to APPLY REDO I also have to select > all the PTF which were already applied to the target zone . > > The challenge is i have close to 3k PTF which I have apply along with > the base FMID. > > Is there a way any other to include 3k automatically and apply REDO > PTF .As coding all the PTF in the control statement would be cumbersome. > > Regards > Jake ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN