The SADUMP data sets are written to in parallel by the stand alone dump program but they aren't really a single striped data set. That's why IPCS COPYDUMP is needed to combine them all into a single data set.
Regards, Mark -- Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 Foundation Certified mailto:m...@mzelden.com Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html On Wed, 9 Jan 2019 16:41:03 +0000, Jesse 1 Robinson <jesse1.robin...@sce.com> wrote: >I don't believe I've needed to send SAD with AMAPDUPL. I'm not aware of the >restriction you refer to. From KC: > >PDUU does not support the following types of input data sets: > Large block interface (LBI) (no BLKSIZE value) > VSAM and direct (DSORG=DA) data sets > Data sets with keys (KEYLEN) > z/OS UNIX files > Concatenated data sets of any type > >'Striped' data sets are not mentioned. >. >. >J.O.Skip Robinson >Southern California Edison Company >Electric Dragon Team Paddler >SHARE MVS Program Co-Manager >323-715-0595 Mobile >626-543-6132 Office ⇐=== NEW >robin...@sce.com > > >-----Original Message----- >From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On >Behalf Of Mark Zelden >Sent: Wednesday, January 09, 2019 8:07 AM >To: IBM-MAIN@LISTSERV.UA.EDU >Subject: (External):AMAPDUPL + Stand Alone Dump > >Happy New Year! > >Does anyone know if there has there ever been a requirement for AMAPDUPL to be >able to directly process / FTP "SYS1.SADMP" (the striped stand alone disk >data set created with the AMDSADDD REXX)? > >I don't have 10 extra 3390-27 volumes laying around to use IPCS COPYDUMP to >create a combined disk copy of the SADUMP to take advantage of AMAPDUPL. >I have to copy the SADUMP to tape then use AMAPDUPL. Saves tersing the data >set, but that is all compared to the speed of using AMAPDUPL for a disk data >set. > >Seems like I only have to send a SADUMP once perhaps twice a year, but when I >need to it would sure be nice to just run AMAPDUPL pointing directly to my >SYS1.SADMP disk data set. IPCS can open and process it correctly, why not >AMAPDUPL? > >Best Regards, > >Mark >-- >Mark Zelden - Zelden Consulting Services - O/OS, OS/390 and MVS ITIL v3 >Foundation Certified mailto:m...@mzelden.com Mark's MVS Utilities: >http://www.mzelden.com/mvsutil.html > > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN