On 12/20/2018 2:36 PM, Jesse 1 Robinson wrote:
By way of update, after studying everyone's suggestions, I ran the job with 
this DD:

//TAPEIN   DD UNIT=(TAPECR,,DEFER),
//   LABEL=(EXPDT=98000),
//   VOL=SER=(nnnnnn),
//   DISP=(OLD,KEEP)

and got pretty much the same result:

IEF403I TAPEANAL - STARTED - TIME=14.37.42
IEC501A M uuuu, nnnnnn,BLP,,TAPEANAL,FATAR
EDG4020I VOLUME nnnnnn REJECTED BY INSTALLATION REJECT DEFINITIONS
EDG4006E VOLUME nnnnnn ON uuuu REJECTED FOR USE BY TAPEANAL, FATAR, TAPEIN, 
OPEN REQUEST FAILED BY DFSMSrmm
IEC502E R uuuu,,     ,,TAPEANAL,FATAR
IEC145I 413-08,IFG0194K,TAPEANAL,FATAR,TAPEIN,uuuu,,  015
SYS18353.T143742.RA000.TAPEANAL.R0161338
IEA995I SYMPTOM DUMP OUTPUT  016
SYSTEM COMPLETION CODE=413  REASON CODE=00000008

CV volume STATUS(MASTER) or STATUS(USER). RMM will not allow a scratch tape to be read under any circumstances. I lost this argument with Mike Wood. Apparently no one ever had to verify the label on a scratch tape...

Regards,
Tom Conley

----------------------------------------------------------------------