On 12/20/2018 2:36 PM, Jesse 1 Robinson wrote:
By way of update, after studying everyone's suggestions, I ran the job with
this DD:
//TAPEIN DD UNIT=(TAPECR,,DEFER),
// LABEL=(EXPDT=98000),
// VOL=SER=(nnnnnn),
// DISP=(OLD,KEEP)
and got pretty much the same result:
IEF403I TAPEANAL - STARTED - TIME=14.37.42
IEC501A M uuuu, nnnnnn,BLP,,TAPEANAL,FATAR
EDG4020I VOLUME nnnnnn REJECTED BY INSTALLATION REJECT DEFINITIONS
EDG4006E VOLUME nnnnnn ON uuuu REJECTED FOR USE BY TAPEANAL, FATAR, TAPEIN,
OPEN REQUEST FAILED BY DFSMSrmm
IEC502E R uuuu,, ,,TAPEANAL,FATAR
IEC145I 413-08,IFG0194K,TAPEANAL,FATAR,TAPEIN,uuuu,, 015
SYS18353.T143742.RA000.TAPEANAL.R0161338
IEA995I SYMPTOM DUMP OUTPUT 016
SYSTEM COMPLETION CODE=413 REASON CODE=00000008
CV volume STATUS(MASTER) or STATUS(USER). RMM will not allow a scratch
tape to be read under any circumstances. I lost this argument with Mike
Wood. Apparently no one ever had to verify the label on a scratch tape...
Regards,
Tom Conley
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN