1. If nobody was using IEFYS, how else would the flower box be printed?

On 2018-11-24 14:48, Seymour J Metz wrote:
>   1. IEFYS is a really old interface; I didn't think anybody was still using 
> it. The best place to look is probably the OS/360 documentation at 
> https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fbitsavers.org%2Fpdf%2Fibm%2F360%2Fos%2FR20.1_Mar71%2FGC28-6550-9_OS_System_Programmers_Guide_Rel_20.1_Jun71.pdf&data=02%7C01%7C%7Cbd270956a79640dbdde708d65245dd84%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C636786857360946751&sdata=SDpk9gv%2BqiCPdB7eUNZdPTtc9Q%2BM8qxr548J8fnU5PI%3D&reserved=0
>
>   2. Doesn't IEFACTRT run under the Initiator TCB? I would expect the storage 
> of the terminating job step to be long gone.
>
>   3. Show your parameter list and return code. You're running under the 
> Initiator, so it may be an issue with your security environment.
>
> --
> Shmuel (Seymour J.) Metz
> https://eur01.safelinks.protection.outlook.com/?url=http:%2F%2Fmason.gmu.edu%2F~smetz3&data=02%7C01%7C%7Cbd270956a79640dbdde708d65245dd84%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C636786857360946751&sdata=GKK3hqgt4uaepi6nw9h80ESrAaOCWmwnBWaw3y3cs%2BA%3D&reserved=0
>
> ________________________________________
> From: IBM Mainframe Discussion List <[email protected]> on behalf of 
> Steff Gladstone <[email protected]>
> Sent: Thursday, November 22, 2018 3:53 PM
> To: [email protected]
> Subject: Re: Looking for an appropriate system exit
>
> Three questions regarding IEFACTRT:
>
> 1. Where is use of IEFYS for writing messages to the JOBLOG documented?
> The example given in the documentation for IEFACTRT is incomplete.  Google
> doesn't seem to locate the doc as well.
>
> 2. I am abending on S0C4 because getmained areas are automatically being
> freed at end of step, before IEFACTRT gets control.  It is not clear to me
> if SUBPOOL alone can solve the problem.  Do I need to specify
> TCBADDR=TCBJSTCB on  the STORAGE macro so that the "input TCB" is the
> job-step TCB?  What course is recommended?
>
> 3. The documentation says one can dynamically allocate within IEFACTRT but
> the BPXWDYN routine returns a non-zero return code.  (Same code that works
> fine in a regular program.)  Is this a limitation of BPXWDYN? Should I code
> an SVC 99 call myself?
>
> Thank you  in advance,
> Steff Gladstone
>
>
>
> On Fri, 5 Oct 2018 at 16:17, Charles Mills <[email protected]> wrote:
>
>> I use the CSVDYNEX interface extensively and it has been nothing but
>> bulletproof in all of my experience. Kudos!
>>
>> Charles
>>
>>
>> -----Original Message-----
>> From: IBM Mainframe Discussion List [mailto:[email protected]] On
>> Behalf Of Elardus Engelbrecht
>> Sent: Friday, October 5, 2018 6:20 AM
>> To: [email protected]
>> Subject: Re: Looking for an appropriate system exit
>>
>> Peter Relson wrote:
>>
>>> When the facility was developed, we took a stab at which existing exits
>> that we thought were most likely to be of help to the most customers. And
>> I'd hope that new exits use it.
>>
>> That was one of the best stabs I got from Big Blue. It saved me an
>> unneeded IPL when one of my SMF exits went down the bit bucket.
>>
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
>>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------