we have the defaults, so 
VSM USEZOSV1R9RULES(YES) 
MEMDSENQMGMT: DISABLE 

Rex

----- Original Message -----

From: "Lizette Koehler" <[email protected]> 
To: [email protected] 
Sent: Friday, October 27, 2017 10:36:02 AM 
Subject: Question on some z/OS Tuning Parms USEZOSV1R9RULES and MEMDSENQMGT 

Dear List - 

I have been reviewing some parms that have been around in z/OS for a few 
years/decades? 

USEZOSV1R9RULES 

VSM USEZOSV1R9RULES(NO|YES): YES causes GETMAIN and STORAGE OBTAIN behavior to 
be unchanged from its historic behavior. NO causes GETMAIN and STORAGE OBTAIN 
behavior for user-region private area subpools that are both below and above 
the 
line to be implemented. Thus DQEs can be merged where possible. The default is 
YES to provide a seamless migration. However, IBM recommends that you specify 
USEZOSV1R9RULES(NO) to obtain a performance benefit for applications with long 
DQE/FQE chains for user-region private area subpools. 

To Display: D DIAG 

MEMDSENQMGT 

Allocation enhancement - MEMDSENQMGMT (Memory-based data set ENQ management) 
- ENQs managed in private storage instead of SWA blocks. Job will be 
non-restartable. 
- Enable via parmlib member or MVS command: 
. ALLOCxx: SYSTEM MEMDSENQMGMT(ENABLE) 
. SETALLOC SYSTEM,MEMDSENQMGMT=ENABLE 
- Exploit with DB2 APAR PM17542 (closed September 2010) 

To display: D ALLOC,OPTIONS 

I was wondering two things 

1) How many are using the new algorithms these two parms brought in? 
2) When you changed to the new functions, did you see any issues? Any products 
that need TLC? 


Are there any other that might also be helpful? 


Thank you 


Lizette Koehler 
statistics: A precise and logical method for stating a half-truth inaccurately 

The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to