Logstream cannot substitute for the LOGREC data set at IPL, which others suggest is required. I checked our MSTJCLxx, but LOGREC is not named there. It is however named in IEASYSxx, where we have coded LOGREC=SYS1.LOGREC.$SYS&SYSCLONE ever since we moved to sysplex in the mid-90s. I cannot recall trying to IPL without LOGREC, but I imagine it would fail.
There are good reasons for moving to logstream, but the ability to IPL is not one of them. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Lizette Koehler Sent: Thursday, June 29, 2017 7:51 AM To: [email protected] Subject: (External):Re: Logstreams So does this mean the problem you are trying to solve by asking about logstreams is Can I prevent my system from not IPL'ing if someone deletes SYS1.LOGREC? Will the logstream still allow me to IPL eve if SYS1.LOGREC is gone? Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Bill Wilkie > Sent: Thursday, June 29, 2017 5:51 AM > To: [email protected] > Subject: Re: Logstreams > > Lizette: > > > I am not using logstreams yet. I am just looking into it. > > > The SYS1.LOGREC data set got deleted on our test system so we couldn't > IPL it. We ran a job from our other system to create a new one and it IPL'd > OK. > > > Thanks > > Bill > > > ________________________________ > From: IBM Mainframe Discussion List <[email protected]> on > behalf of Lizette Koehler <[email protected]> > Sent: Thursday, June 29, 2017 12:45 PM > To: [email protected] > Subject: Re: Logstreams > > When you say you deleted a logstream - which one? > > If it is for Logrec, did you have the SYS1.LOGREC dataset still > cataloged and on the system? > > What was the corrective action that allowed you to IPL > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List > > [mailto:[email protected]] On Behalf Of Bill Wilkie > > Sent: Thursday, June 29, 2017 2:32 AM > > To: [email protected] > > Subject: Re: Logstreams > > > > We accidentally deleted Logrec on one system, and couldn't IPL. Not > > sure if logstream being available would have made a difference. > > > > > > Bill > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN