I have not seen a 3290 in years, but I think the next few ports in the 3174 become dead ports. So if you are defining 4 sessions the next three ports to the one you plug in the coax in the 3174 become dead. You still need the VTAM/LU stuff defined. I think. Like I said I have not seen a 3290 or a 3174 in years.
Thanks.. Paul Feller AGT Mainframe Technical Support -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Dave McGuire Sent: Friday, April 28, 2017 15:00 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: new member, need old iron assistance Hello Paul, yes I think I have that set up correctly. But this got me thinking, and I may be misunderstanding something about the 3174 and its handling of multiple sessions. What I've done is configured MLT (Multiple Logical Terminal) support on the 3174, which works well on the other terminals; I can switch back and forth between four independent sessions on the same terminal. Only one coax port on the 3174 is used for this. I had assumed that this is how the 3290 handles multiple sessions. Your suggestion of allocating a total of four ports on the 3174 for the 3290 got me thinking that perhaps it does this a different way; do you mean allocating four actual physical coax ports on the 3174 for the 3290? -Dave On 04/28/2017 01:48 PM, Feller, Paul wrote: > If I remember correctly if you plan on doing multiple screens on the > 3290 you also have to setup the 3174 to handle it. As an example if > you want 4 3270 mod4s you have to let the 3174 know you will be using > up a total of 4 ports on the 3174. > > Thanks.. > > Paul Feller AGT Mainframe Technical Support > > -----Original Message----- From: IBM Mainframe Discussion List > [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Dave McGuire Sent: > Friday, April 28, 2017 12:31 To: IBM-MAIN@LISTSERV.UA.EDU Subject: > new member, need old iron assistance > > Hi folks, new list member here. I come seeking the wisdom of gurus. > Please forgive any breach of protocol. > > I'm looking for some assistance with some older iron, a 3290 plasma > terminal. I have it partially functional, connected to a 3174, and > can get into the terminal's setup panels, but those panels are > essentially useless without documentation. I'm not getting any > sessions through the 3174 to the 3290, so something is wrong > somewhere. Other terminals connected to the same 3174 reach hosts > just fine. It's my hope that I'll be able to figure it out once I > find the appropriate documentation. > > I believe the setup panels are documented in publication GA23-0241, > which doesn't appear to be available online anywhere. > > Would anyone here have a copy of that manual, or any other relevant > material, on a dusty bookshelf? Or would anyone with knowledge of > 3290+3174 configuration be willing to give me some assistance? > > Any assistance is greatly appreciated. > > Respectfully, -Dave > -- Dave McGuire President/Curator, Large Scale Systems Museum New Kensington, PA ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN