You can concatenate them or just build a new SMPPTS and change the name in the 
DDEF 

https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.2.0/com.ibm.zos.v2r2.gim2000/dspts1.htm


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Dan Little
Sent: Thursday, March 16, 2017 7:58 PM
To: [email protected]
Subject: Re: Can SMPPTS datasets be consolidated?

I thought the SMMPTSx DDDEF was recorded in the global zone and that 
consolidating could not easily be done.


Dan


On Thu, Mar 16, 2017 at 19:26 Gibney, Dave <[email protected]> wrote:

> Has this always been so. Sometime ago (1.7, 1.9) I had ACCEPT fail 
> because I had compressed and moved members into lower sequenced 
> SMPPTSn At least I think I remember this. I've just always added 
> another SMPPTSz ever since.
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List 
> > [mailto:[email protected]] On Behalf Of Jesse 1 Robinson
> > Sent: Thursday, March 16, 2017 3:45 PM
> > To: [email protected]
> > Subject: Re: Can SMPPTS datasets be consolidated?
> >
> > SMP/E does not keep a permanent record of which PTS holds a 
> > particular sysmod. On every query, the concatenated PTS libraries 
> > are searched. If
> the
> > sysmod is found, the particular library is named, otherwise 'not found'.
> This
> > allows you to freely manipulate the libraries and their content. 
> > Worst
> case,
> > after consolidating PTS libraries, exit and re-enter the SMP/E dialog.
> >
> > .
> > .
> > J.O.Skip Robinson
> > Southern California Edison Company
> > Electric Dragon Team Paddler
> > SHARE MVS Program Co-Manager
> > 323-715-0595 Mobile
> > 626-543-6132 Office ⇐=== NEW
> > [email protected]
> >
> >
> > -----Original Message-----
> > From: IBM Mainframe Discussion List 
> > [mailto:[email protected]] On Behalf Of Gibney, Dave
> > Sent: Thursday, March 16, 2017 1:37 PM
> > To: [email protected]
> > Subject: (External):Re: Can SMPPTS datasets be consolidated?
> >
> > I am not sure the process. I'd advise adding more secondary PPTS
> datasets.
> > SMP/E remembers which PPTS a given PTF is in.
> >
> > > -----Original Message-----
> > > From: IBM Mainframe Discussion List 
> > > [mailto:[email protected]] On Behalf Of Allan Staller
> > > Sent: Thursday, March 16, 2017 1:34 PM
> > > To: [email protected]
> > > Subject: Re: Can SMPPTS datasets be consolidated?
> > >
> > > YES-----Original Message-----From: IBM Mainframe Discussion List 
> > > [mailto:[email protected]] On Behalf Of Herring, BobbySent:
> > > Thursday, March 16, 2017 3:30 PMTo: IBM-
> > [email protected]:
> > > Can SMPPTS datasets be consolidated?I am in the process of 
> > > receiving a large RSU maintenance order. I have filled up three 
> > > SMPPTS datasets that were not defined large enough.Can these be 
> > > merged and consolidated into one or two much larger datasets?Bobby 
> > > HerringTexas Farm Bureau
> >
> > --------------------------------------------------------------------
> > -- For IBM-MAIN subscribe / signoff / archive access instructions, 
> > send email to [email protected] with the message: INFO 
> > IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to