Hi Dana, Do I have to stop the two CECs first before do the change. Mohamed
Sent from my iPhone > On Mar 16, 2017, at 8:00 PM, Dana Mitchell <[email protected]> wrote: > > Mohamed, > > You will have to change the CTN on the DR CEC and the TEST CEC to PRODSTP. > Then I think all LPARs on those two CECs will need to be IPLed to be aware of > the new time source. It's been a while since we've change any of our STP > configuration. > > Dana > >> On Thu, 16 Mar 2017 06:20:07 +0000, Mohamed Juma <[email protected]> wrote: >> >> Hi dear We are right now in project of Disaster Recovery Site, we have >> only one CEC in DR to combined both TEST and PROD, in HO three CECs for >> PROD, and one CEC for TEST.The PROD in one CTN STP called (PRODSTP) the >> TEST environment in Active/Active between the two sites in one Sysplex using >> one CTN STP (TESTSTP).We are in the phase of connecting the PROD system to >> the DR site CEC for Active/Active implementation, so we have to merge the >> two CTN in only one CTN STP and also using one NTP server in each site. >> There is any way to do that without stopping any of my systems (I have a >> doubt to find such scenario),I want some recommendation for such migration >> with the minimum stopping to my Systems (I can live with stopping TEST >> system for some time) Thanks for help Mohamed Juma >> >> >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN