on SDSF try selec ting the output DD using a ? besides the job's SYSOUT 
then scroll over to the left until you see the JES2 dataset attributes 
you'll see the record format and the LRECL of the JES dataset 
Hope I don't loose the formatting here but 

something like this you'll see 



NP DDNAME ct TRd-Time TRd-Date TSt-Time TSt-Date RecFM W OCopyCnt LRecL 
JESMSGLG 0:00:00 0000.000 0:00:00 0000.000                     UA NO            
  133 
JESJCL 0:00:00 0000.000 0:00:00 0000.000                             V NO       
         132 
JESYSMSG 0:00:00 0000.000 0:00:00 0000.000                    VA NO             
 133 
SYSOUT 0:00:00 0000.000 0:00:00 0000.000                                    VBA 
NO 121 
MFPMSGDS 0:00:00 0000.000 0:00:00 0000.000                        VBA NO 121 



----- Original Message -----

From: "venkat kulkarni" <venkatkulkarn...@gmail.com> 
To: IBM-MAIN@LISTSERV.UA.EDU 
Sent: Thursday, December 29, 2016 8:51:06 AM 
Subject: Re: Xdc output print 

Yes, I tried with VB as record format snd then to 1024 as lrecl and 1024 in 
block size and I tried fb with 240 lrecl and blksize with 3120 but still 
same issue 

On Dec 29, 2016 17:49, "Jousma, David" <david.jou...@53.com> wrote: 

> On the XDC panel at the bottom is the DCB info for allocating.  Including 
> LRECL.   Just make it bigger! 
> 
> _________________________________________________________________ 
> Dave Jousma 
> Manager Mainframe Engineering, Assistant Vice President 
> david.jou...@53.com 
> 1830 East Paris, Grand Rapids, MI  49546 MD RSCB2H 
> p 616.653.8429 
> f 616.653.2717 
> 
> -----Original Message----- 
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On 
> Behalf Of venkat kulkarni 
> Sent: Thursday, December 29, 2016 9:47 AM 
> To: IBM-MAIN@LISTSERV.UA.EDU 
> Subject: Xdc output print 
> 
> Hello Group, 
> 
> We have big lengthy report in sdsf and I was trying xdc to save report 
> into PDs member.but the data from right side in truncated. I am unable to 
> fix this issue. Do we have any restriction on using record length size in 
> PDs or any parameter which can help me resolving this issue. 
> 
> Regards 
> Venkat 
> 
> ---------------------------------------------------------------------- 
> For IBM-MAIN subscribe / signoff / archive access instructions, send email 
> to lists...@listserv.ua.edu with the message: INFO IBM-MAIN 
> 
> This e-mail transmission contains information that is confidential and may 
> be privileged.   It is intended only for the addressee(s) named above. If 
> you receive this e-mail in error, please do not read, copy or disseminate 
> it in any manner. If you are not the intended recipient, any disclosure, 
> copying, distribution or use of the contents of this information is 
> prohibited. Please reply to the message immediately by informing the sender 
> that the message was misdirected. After replying, please erase it from your 
> computer system. Your assistance in correcting this error is appreciated. 
> 
> 
> ---------------------------------------------------------------------- 
> For IBM-MAIN subscribe / signoff / archive access instructions, 
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN 
> 

---------------------------------------------------------------------- 
For IBM-MAIN subscribe / signoff / archive access instructions, 
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN 


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to