They are in both catalogs. I am not currently concerned with the CA-1 catalog since CA-1 normally scratches the tape when HSM recycles a tape. Anyway, I can handle CA-1 when/if I get HSM cleaned up.

I am trying to clean-up un-readable 3490 tapes listed in the output from:
HSEND LIST TTOC SELECT(FULL) ODS ('xxxxxxx')

Tony Thigpen

Linda wrote on 12/14/2016 01:37 AM:
Hi Tony,

Listed in the system catalog or the HSM tape catalog, both?

You should be able to list the catalogue entries, and IF they match, you could 
reset the HSM expiration values to a date in the close future, and let them 
expire through normal HSM processing.

Once the datasets are expired and the tapes are scratched you should be able to 
remove or replace the volumes or mark them as deleted.

HTH,

Linda

Sent from my iPhone

On Dec 13, 2016, at 2:02 PM, Tony Thigpen <[email protected]> wrote:

I am looking at my HSM TTOC listing. I have 3 old 3490s that are still listed. 
I actually have the tapes, but they are unreadable. On two of them, I get a 
label error:
IEC514D DCK OR LBL ERR

On the other one, the TTOC shows:
RC0378I TTOC RECORD AND TAPE MEDIA CONTENTS ARE INCONSISTENT....

Since I can't migrate these volumes, how do I just delete these active tapes 
from HSM? They are at least 15 years old so I am not worried about the data 
that may have been on them.

--
Tony Thigpen

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to