I'd make a new PROC with COND=(8,LT) for subsequent steps.
 
https://www.ibm.com/support/knowledgecenter/SSLTBW_2.1.0/com.ibm.zos.v2r1.ie
ab600/xexcond.htm
 
 
In a message dated 8/26/2016 1:56:18 A.M. Central Daylight Time,  
[email protected] writes:

We've  just upgraded to Cobol V5R1 and in the new versión appears a new 
warning  message "IGYCB7300-W   The code from lines xxxx in program 'xxxxxx'  
can never be executed and was therefore discarded". This message doesn't  
appear in V4R2, now the compilation step finishs with RC=04 and the job  
cancels. 
Does exist any option to change the RC with this warning from  RC=04 to 
RC=00?. It would be a workaround meanwhile we correct all the  programs 
affected.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to