On Tue, 26 Apr 2016 13:25:45 -0700, Ed Jaffe <[email protected]> 
wrote:

>On 4/26/2016 1:13 PM, Mark Zelden wrote:
>> When my client replaces their CPCs the name is kept the same.  For example
>> CPCA, CPCB, CPCC, ...  etc.   The RACF profile is based on that name so
>> nothing needs to be changed in RACF.
>
>A RACF SEARCH command produces the following profiles beginning with HWI
>in the FACILITY class:
>
>HWI.APPLNAME.HWISERV
>HWI.IBM390PS.P00C9632.HWISERV
>HWI.TARGET.IBM390PS.P00C9632
>HWI.TARGET.IBM390PS.P00C9632.* (G)
>
>The P00C9632 qualifier is based on the serial number of our old CPC. Our
>z13s was not an MES upgrade from the zBC12. It was a "net new" machine
>and -- as such -- has a brand new serial number. (The zBC12 was moved to
>our DR site.)
>

It sounds like that was your CPC name also.    I have RACF profiles like the 
following
and nothing needed to be changed when we rolled in 5 z13s late last year.  

HWI.CAPREC.IBM390PS.CF01.* (G)  
HWI.CAPREC.IBM390PS.CPCA.* (G)  
HWI.CAPREC.IBM390PS.CPCB.* (G)  
HWI.CAPREC.IBM390PS.CPCC.* (G)  
HWI.CAPREC.IBM390PS.CPCD.* (G)  
HWI.TARGET.IBM390PS.CF01.* (G)  
HWI.TARGET.IBM390PS.CPCA.* (G)  
HWI.TARGET.IBM390PS.CPCB.* (G)  
HWI.TARGET.IBM390PS.CPCC.* (G)  
HWI.TARGET.IBM390PS.CPCD.* (G)  

The RACF calls are based on the CPC name, not the definition in the HMC 
under the API settings. Since we kept the CPC names the change, nothing
had to change in RACF.  IBM copied over HMC settings as part of the
migration (all 5 boxes, of which one is a stand alone CF, were all
"net new" and the old ones returned to IBM). 

https://www.ibm.com/support/knowledgecenter/SSLTBW_2.1.0/com.ibm.zos.v2r1.ieac100/iea3c1_Authority_to_the_particular_resource.htm

Best regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS
ITIL v3 Foundation Certified
mailto:[email protected]
Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html
Systems Programming expert at http://search390.techtarget.com/ateExperts/
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN