Thanks. That looks very helpful. I am visiting customers and headed to IBM. I
will give it a shot as I can.
Your analysis of my need is correct.
CharlesSent from a mobile; please excuse the brevity
-------- Original message --------
From: Neil Duffee <[email protected]>
Date: 04/07/2016 5:06 PM (GMT-05:00)
To: Charles Mills <[email protected]>
Cc: IBM-Main <[email protected]>
Subject: RE: How force dataset non-SMS?
Caveat: daily digestion causes response delays...
Charles: I'm gonna go back over some territory to make sure I understand the
*original* purpose. I *believe* you simply want a multi-volume dataset for
SMF17 (Scratch/delete) work in the simplest manner possible. It can be SMS or
no, can be any dsOrg, & doesn't require large space. (or any records, even)
All good so far?
Presuming a yes, I point out that PS files (not EXT) max@16 extents/volume.
Given that, combine IEBDG (I dropped the suggesting author, sorry), [1] with
Tom's SPACE=(TRK,(1,1)),UNIT=(SYSALLDA,5) or an SMS DataClas that has
VolCount/DynVolCnt>1. You should get 16 tracks on each volume until x37 for
volume count. I'd even go with LRECL>29k (0.5 track length) to get 16 records
per volume. The creating job should take more time to start/stop than output
the necessary bytes.
[1] You could probably IDCAMS PRINT something simple as well if you use the
large record size.
--------> signature = 8 lines follows <--------
Neil Duffee, Joe Sysprog, uOttawa, Ottawa, Ont, Canada
telephone:1 613 562 5800 x4585 fax:1 613 562 5161
mailto:NDuffee of uOttawa.ca http:/ /aix1.uOttawa.ca/ ~nduffee
"How *do* you plan for something like that?" Guardian Bob, Reboot
"For every action, there is an equal and opposite criticism."
"Systems Programming: Guilty, until proven innocent" John Norgauer 2004
"Schrodinger's backup: The condition of any backup is unknown until a restore
is attempted." John McKown 2015
-----Original Message-----
From: Charles Mills [mailto:[email protected]]
Sent: April 6, 2016 11:36
Subject: Re: How force dataset non-SMS?
Still the same answer. I want a multi-volser dataset and SMS is getting in the
way of that.
Pure local test. No customers in the problem set.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Paul Gilmartin
Sent: Wednesday, April 06, 2016 10:15 AM
To: [email protected]
Subject: Re: How force dataset non-SMS?
On 2016-04-06, at 00:54, Vernooij, CP (ITOPT1) - KLM wrote:
> ... Why do you need a non-managed dataset? ...
>
I might imagine tesing. The OP might be operating as an and desiring to test
code that shoulc work in any possible customer environment, either SMS or
non-SMS.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,