Hmm, thanks for that.  It looks like the EA value was NO instead of YES.  
I'll have to figure out how that happened.

Greg 

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Lizette Koehler
Sent: Thursday, February 25, 2016 11:21 AM
To: [email protected]
Subject: Re: VSAM file not extending to new volume

Check for this in your data class
                        DATA CLASS DISPLAY                   Page 2 of 5
                                                                               
 CDS Name  . . . . . : ACTIVE                                                  
 Data Class Name . . : DIRECT                                                   
 
                                                                               
 Data Set Name Type  . . . . . : EXTENDED                                      
   If Extended . . . . . . . . : REQUIRED                                      
   Extended Addressability . . : YES                                            
   Record Access Bias  . . . . : USER                                          
 Space Constraint Relief . . . : NO                                            
------------------------------------------------------------------------------



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to