We are planning to upgrade to z/OS V2.2 and with it COBOL v5
.
Im being told that programs compiled with COBOL 5 must have there load modules 
reside in a PDSE. So we are undertaking a conversion from PDS to PDSE so that a 
program compiled with COBOL 5 will link edit into a PDSE.
.
.
I have no objections to this, I just cant get a straight answer as to why is a 
PDSE necessary is necessary for COBOL 5 programs.
.
I have not heard of this requirement with Assembler. What About PL/I and C, are 
they required to have load modules stored in a PDSE ?
.
.
IBMLInk told me that the Format of a COBOL 5 program is different and as such 
requires a PDSE. 
.
Is it the COBOL Compiler or the Binder/Linkage Editor that has the requirement. 
As Far as I know existing programs compiled with pre COBOL 5 compilers can 
execute out of a PDSE.
.
.
So why cant a application programmer continue to use a Complier prior to COBOL 
5 and link edit into the same PDS/E.
.
.
Im Not understanding what/why COBOL 5 needs a PDSE.
.

Paul 


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to