On Thu, Sep 17, 2015 at 12:10 AM, Meenakshi, Vinoth - CW <
[email protected]> wrote:

> Hi Ant,
>
> We couldn't able to access commands from master console or HMC, since the
> system went onto wait-state.
>
> Central processor (CP) 0 is in a nonrestartable stopped state due to a
> System Control Program (SCP) initiated reset of the I/O interface for
> partition LPAR4.
> The disabled wait program status word (PSW) is
> 000200008000000000000000000040a2.
>
> Could you assist how we move forward from here. Thanks
>

​Glad you have had your problem resolve (from later message in this thread).
Hard Wait codes are in the "MVS System Codes" manual. The good information
is the last 3 hex digits: 0A2
>From z/OS 1.12 (what we are running here):
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/IEA2H7B0/3.90
<quote>
*Explanation:* Cross-system coupling facility (XCF) or cross-system
extended services encountered a non-recoverable error and stopped the
system. The system also issues this wait state in response to an operator
request to stop the system. See z/OS MVS Diagnosis: Reference
<http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/DOCNUM/GA22-7588/CCONTENTS?>
for
information on diagnosing sysplex problems.
</quote>

At my shop, I do the shutdowns and IPLs. I get the above every time after I
do the z/OS operator command: V XCF,lpar,OFFLINE
​



>
> Regards,
> Vinoth M
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Anthony Thompson
> Sent: Thursday, September 17, 2015 9:48 AM
> To: [email protected]
> Subject: Re: IPL Shutdown Problem
>
> ROUTE command not working is a completely separate issue. It won't happen
> if that LPAR is outside of the sysplex. You'll need a console on that
> system. Use the HMC if you need to, assuming you have one.
>
> Try the F OMVS, STOPPFS=FZS command on a SYS9 console. F
> BPXOINIT,SHUTDOWN=FORKINIT should bring down both ZFS and OMVS.
>
> $PJES2,ABEND if you absolutely have to.
>
> Ant.
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Meenakshi, Vinoth - CW
> Sent: Thursday, 17 September 2015 1:23 PM
> To: [email protected]
> Subject: Re: IPL Shutdown Problem
>
> Thanks Ant & Lizette.
>
> F OMVS,STOPPFS=ZFS command worked and we were able to bring down ZFS for
> one systemSYS3 and for other system SYS9 we are facing an issue.
>
> OMVS is down and we tried to issue STOPPFS=ZFS command and it's not
> allowing.
>
> RESPONSE=SYS1      IEE618I  ROUTE   COMMAND REJECTED.  SYS9
>
> I think the system is out of sysplex now and still the below STC are
> running in SYS9.
>
>       ZFS      STC03291 OMVS       15 EXECUTION          SYS9  SYS9
>       SYSLOG   STC09890 +MASTER+   15 EXECUTION          SYS9  SYS9
>
> Regards,
> Vinoth M
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Anthony Thompson
> Sent: Thursday, September 17, 2015 8:59 AM
> To: [email protected]
> Subject: Re: IPL Shutdown Problem
>
> Stop the ZFS address space. It should stop as part of OMVS shut down
> anyway, but that's probably post-JES2 completion at your site. Issue
> command F OMVS,STOPPFS=ZFS. SYSLOG should close as part of normal JES2 shut
> down. Under z/OS 2.2, it is not recommended to run ZFS processing in its
> own address space.
>
> Ant.
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Lizette Koehler
> Sent: Thursday, 17 September 2015 12:53 PM
> To: [email protected]
> Subject: Re: IPL Shutdown Problem
>
> The list is not the best place for an urgent issue.  But we will try to
> help.
>
> If this is PRODUCTION, Just take a Stand alone dump and IPL.
> If this is any other system  - how long can you be down before you IPL.
>
> Normally I do the SA Dump and IPL.  I worry about why later.
>
> You do not want to spend a lot of time trying to resolve things when you
> are IPL'ing.  Especially if this is a critical system.
>
> You may need IBM's assistance in determine your shutdown issue, if you
> have not used IPCS on a Stand alone dump.
>
>
> Lizette
>
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of Meenakshi, Vinoth - CW
> > Sent: Wednesday, September 16, 2015 8:03 PM
> > To: [email protected]
> > Subject: IPL Shutdown Problem
> >
> > Hi All,
> >
> > We are having issue with bringing down the JES2,two of the STC are
> > running and it's not coming down. Even Purge command is not working.
> >
> >        ZFS      STC03291 OMVS       15 EXECUTION          SYS9  SYS9
> >       SYSLOG   STC09890 +MASTER+   15 EXECUTION          SYS9  SYS9
> >
> > Even we can't able issue command from other systems.
> >
> > RESPONSE=SYS9      IEE707I $DA,X    NOT EXECUTED
> >
> > Kindly guide us on this.
> >
> > Thanks.
> > Vinoth M
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 

Schrodinger's backup: The condition of any backup is unknown until a
restore is attempted.

Yoda of Borg, we are. Futile, resistance is, yes. Assimilated, you will be.

He's about as useful as a wax frying pan.

10 to the 12th power microphones = 1 Megaphone

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to