No. It is 2.1. There is a fairly old Apar for the same reason code OA36228.
On Monday, May 25, 2015, Thomas Berg <[email protected]> wrote: > Is that applicable on zOS 1.13 ? As that is what the prod system is at. > (Looked at OA43214 - it said Software version 210.) > > > > Best Regards, > Thomas Berg > ___________________________________________________________________ > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > Interactive is ‘manual.’ Batch is ‘automatic.’ > > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:[email protected] > <javascript:;>] On Behalf Of Dan > > Little > > Sent: Tuesday, May 26, 2015 4:40 AM > > To: [email protected] <javascript:;> > > Subject: Re: Corrupt PDSE - IGW699I PDSE Directory Validation > Unsuccessful > > > > Sounds like oa45027. > > > > On Monday, May 25, 2015, Thomas Berg <[email protected] > <javascript:;>> wrote: > > > > > I checked the restored one. It was ok. > > > > > > I'm currently running IEBPDSE against the failing version, this time in > > > the prod system (where I was just "hanging" when trying to browse it). > > > When running the same job in the DEV system it took just 4 seconds, > but now > > > in the prod system it is still running after >10 minutes. It consumes > CPU > > > time but no EXCP (stands still at 4 EXCP). When run in the DEV system > it > > > consumed 10213 EXCP. > > > > > > > > > > > > Best Regards, > > > Thomas Berg > > > ___________________________________________________________________ > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > > > -----Original Message----- > > > > From: IBM Mainframe Discussion List [mailto:[email protected] > <javascript:;> > > > <javascript:;>] On Behalf Of > > > > Mark Jacobs - Listserv > > > > Sent: Tuesday, May 26, 2015 4:04 AM > > > > To: [email protected] <javascript:;> <javascript:;> > > > > Subject: Re: Corrupt PDSE - IGW699I PDSE Directory Validation > > > Unsuccessful > > > > > > > > Yea, it looks damaged to me too. I'd still recommend that you > validate > > > > the integrity of the restored dataset, just to be safe. > > > > > > > > Mark Jacobs > > > > > > > > > Thomas Berg <mailto:[email protected] <javascript:;> > <javascript:;>> > > > > > May 25, 2015 at 10:00 PM > > > > > Tried on another prodsystem. Got this: > > > > > > > > > > IGW699I PDSE Directory Validation Unsuccessful > > > > > IEA995I SYMPTOM DUMP OUTPUT > > > > > SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024 > > > > > TIME=03.59.10 SEQ=44968 CPU=0000 ASID=01F8 > > > > > PSW AT TIME OF ERROR 075C1000 88FDA690 ILC 2 INTC 0D > > > > > NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME > > > > > NAME=UNKNOWN > > > > > DATA AT PSW 08FDA68A - 58F05048 0A0DB219 0000A788 > > > > > AR/GR 0: 008FF6C8/01188012 1: 00000000/040F4000 > > > > > 2: 00000001/00FDB9A0 3: 00000000/7EC6E268 > > > > > 4: 00000002/00007703 5: 00000000/7EC73400 > > > > > 6: 00000000/7EC6E060 7: 00000000/00FE0548 > > > > > 8: 00000000/00FE05B8 9: 00000001/7EC6E268 > > > > > A: 00000000/7EC73868 B: 00000000/00000000 > > > > > C: 00000000/08FDA012 D: 00000000/7EC73778 > > > > > E: 00000000/88FDA682 F: 00000000/00000024 > > > > > END OF SYMPTOM DUMP > > > > > DESC:PDSE structure is corrupted > > > > > ERROR NUM:103 > > > > > DSN:SYS6.IDI.PROD5.HIST.FEL > > > > > VOLSER:GEM040 > > > > > ADPages:10169 IXRecords:405168 > > > > > ADPagesInCore:159 ADPagesRead:10010 > > > > > ADTreeLevels:3 > > > > > NDPages:21 IXRecords:2460 > > > > > NDPagesInCore:7 NDPagesRead:14 > > > > > NDTreeLevels:2 > > > > > AD ND Tree Nodes:2430 > > > > > Version:1 > > > > > Orphan Pages:4682 > > > > > RC:4 RS:01188012 > > > > > IGW702I PDSE Directory Validation Unsuccessful > > > > > DESC:<AD> Structure is corrupted > > > > > LTK:D561C14040404040404040404040404040404040 > > > > > ERROR NUM:1 > > > > > DSN:SYS6.IDI.PROD5.HIST.FEL > > > > > VOLSER:GEM040 > > > > > RC:4 RS:01188012 R14:08E8D2A4 > > > > > RPN:N/A > > > > > VPTVFN:N/A > > > > > IEC036I 002-A4,IGC0005E,S000TBE,KAT30,ISP03594,786B,GEM040, > > > > > SYS6.IDI.PROD5.HIST.FEL > > > > > IRX0250E System abend code 002, reason code 00000164. > > > > > IRX0255E Abend in host command SELECT or address environment > routine > > > > > ISPEXEC. > > > > > *** > > > > > > > > > > > > > > > > > > > > Best Regards, > > > > > Thomas Berg > > > > > ___________________________________________________________________ > > > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > ---------------------------------------------------------------------- > > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > > send email to [email protected] <javascript:;> > <javascript:;> with the > > > message: INFO IBM-MAIN > > > > > Mark Jacobs - Listserv <mailto:[email protected] > <javascript:;> <javascript:;> > > > > > > > > > May 25, 2015 at 9:50 PM > > > > > Three more questions. > > > > > > > > > > 1. Do you have all the required toleration maintenance applied on > your > > > > > 1.13 system? > > > > > 2. Does the hang occur on all systems in the sysplex or just one? > > > > > 1. If only on one, can you recycle the SMSPDSE1 address space > and > > > > > see if that fixes the problem? > > > > > > > > > > Mark Jacobs > > > > > > > > > > > > > > > Thomas Berg <mailto:[email protected] <javascript:;> > <javascript:;>> > > > > > May 25, 2015 at 9:47 PM > > > > > BTW, we are on zOS 2.1 in the DEV system and zOS 1.13 in the prod > > > system. > > > > > > > > > > > > > > > > > > > > Best Regards, > > > > > Thomas Berg > > > > > ___________________________________________________________________ > > > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > ---------------------------------------------------------------------- > > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > > send email to [email protected] <javascript:;> > <javascript:;> with the > > > message: INFO IBM-MAIN > > > > > Mark Jacobs - Listserv <mailto:[email protected] > <javascript:;> <javascript:;> > > > > > > > > > May 25, 2015 at 9:27 PM > > > > > If you take a physical dump of the dataset and send it into IBM for > > > > > analysis they might be able to get to the root cause. Assuming > you're > > > > > on zOS 1.13 or higher did you execute IEBPDSE against the restored > > > > > dataset to verify its structure? > > > > > > > > > > Mark Jacobs > > > > > > > > > > > > > > > Thomas Berg <mailto:[email protected] <javascript:;> > <javascript:;>> > > > > > May 25, 2015 at 9:23 PM > > > > > AFAIK it should have a very low probability. This due to that those > > > > > that can access from outside of the Sysplex (special sysprogs) have > > > > > neither reason or interest of doing that. And this is 3.00 AM here. > > > > > (At least the operator I spoke to had no knowledge of anyone else > that > > > > > me working at this time.) > > > > > > > > > > I have restored a backup from yesterday now so the immediate > problem > > > > > is solved. (And saved the corrupted PDSE in case anyone except me > is > > > > > interested.) > > > > > > > > > > > > > > > > > > > > Best Regards, > > > > > Thomas Berg > > > > > ___________________________________________________________________ > > > > > Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ) > > > > > > > > > > Interactive is 'manual.' Batch is 'automatic.' > > > > > > > > > > > > > > > > > > > > > ---------------------------------------------------------------------- > > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > > send email to [email protected] <javascript:;> > <javascript:;> with the > > > message: INFO IBM-MAIN > > > > > > > > -- > > > > > > > > Mark Jacobs > > > > Time Customer Service > > > > Technology and Product Engineering > > > > > > > > The standard you walk past is the standard you accept. > > > > Lt. Gen. David Morrison > > > > > > > > > ---------------------------------------------------------------------- > > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > > send email to [email protected] <javascript:;> > <javascript:;> with the message: > > > INFO IBM-MAIN > > > > > > ---------------------------------------------------------------------- > > > For IBM-MAIN subscribe / signoff / archive access instructions, > > > send email to [email protected] <javascript:;> <javascript:;> > with the message: > > > INFO IBM-MAIN > > > > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] <javascript:;> with the message: > INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] <javascript:;> with the message: > INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN