Could it have been shared(R/W) outside of a sysplex boundary?

Mark Jacobs

Thomas Berg <mailto:[email protected]>
May 25, 2015 at 8:43 PM
Got a corrupt PDSE. Will throw the problem at some of the responsible sysprogs. But in the meantime I wonder if any of the esteem members of this list can give some hints leading to the cause.

Got this when tying a browse from ISPF 3.4 (linecmd B):

IGW699I PDSE Directory Validation Unsuccessful
DESC:PDSE structure is corrupted
ERROR NUM:103
DSN:SYS6.IDI.PROD5.HIST
VOLSER:GEM040
ADPages:10169 IXRecords:405168
ADPagesInCore:159 ADPagesRead:10010
ADTreeLevels:3
NDPages:21 IXRecords:2460
NDPagesInCore:7 NDPagesRead:14
NDTreeLevels:2
AD ND Tree Nodes:2430
Version:1
Orphan Pages:4682
RC:4 RS:01188012
IGW702I PDSE Directory Validation Unsuccessful
DESC:<AD> Structure is corrupted
LTK:D561C14040404040404040404040404040404040
IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024
TIME=02.28.25 SEQ=58662 CPU=0000 ASID=0457
PSW AT TIME OF ERROR 075C1000 888B9690 ILC 2 INTC 0D
NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME
NAME=UNKNOWN
DATA AT PSW 088B968A - 58F05048 0A0DB219 0000A788
AR/GR 0: 007FF6C8/01188012 1: 00000000/040F4000
2: 00000001/00FDB9A0 3: 00000000/7B1A2268
4: 00000002/00007703 5: 00000000/7B1A7400
6: 00000000/7B1A2060 7: 00000000/00FE0548
8: 00000000/00FE05B8 9: 00000001/7B1A2268
A: 00000000/7B1A7868 B: 00000000/00000000
C: 00000000/088B9012 D: 00000000/7B1A7778
E: 00000000/888B9682 F: 00000000/00000024
END OF SYMPTOM DUMP
ERROR NUM:1
DSN:SYS6.IDI.PROD5.HIST
VOLSER:GEM040
RC:4 RS:01188012 R14:0876C2A4
RPN:N/A
VPTVFN:N/A
IEC036I 002-A4,IGC0005E,S000TBE,KAT30,ISP02264,786B,GEM040,
SYS6.IDI.PROD5.HIST
ERROR DESCRIPTION: IEC036I
Unable to complete the READ against the PDSE directory due to an error
return code from the SMS service used to obtain directory information.
END ERROR DESCRIPTION: IEC036I
IRX0250E System abend code 002, reason code 00000164.
IRX0255E Abend in host command SELECT or address environment routine ISPEXEC.
***


The dataset is a Fault Analyzer dump pdse. Is populated from productions abends (in another system - same Sysplex). Was browsing from the dev system. We have 7 other similar datasets, all populated from the prod system and mostly viewed from the dev system. First time for me of a corrupt PDSE causing an abend like this.



Best Regards,
Thomas Berg
___________________________________________________________________
Thomas Berg Specialist zOS/RQM/IT Delivery Swedbank AB (Publ)

Interactive is 'manual.' Batch is 'automatic.'

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN


Please be alert for any emails that may ask you for login information or directs you to login via a link. If you believe this message is a phish or aren't sure whether this message is trustworthy, please send the original message as an attachment to '[email protected]'.


--

Mark Jacobs
Time Customer Service
Technology and Product Engineering

The standard you walk past is the standard you accept.
Lt. Gen. David Morrison

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to