We IPL CLPA *every* time. Ever since we accidentally IPLed from the wrong 
rotating sysres. Coming up at an unexpected maintenance level might be 
annoying, but try it sometime when LINKLIB is at one OS maintenance level and 
LPA is at a different level. How long will take you to figure out what's wrong? 
Recommendation: CLPA every time.  

.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Binyamin Dissen
Sent: Monday, April 27, 2015 12:19 PM
To: [email protected]
Subject: Re: DUMP parm recommendation

On Mon, 27 Apr 2015 13:01:38 -0400 "Richards, Robert B."
<[email protected]> wrote:

:>Going to z/OS 2.1 and am looking for a good recommendation for a default 
SDATA.

:>My WebSphere guy asked for this:

:>SDATA=(CSA,,SQA,RGN,TRT,GRSQ,LPA,LSQA,SUM,NUC,PSA,SWA,ALLNUC) and I am 
thinking of adding HCSAByASID,HCSANoOwner,HCSASysOwner.

:>Advice? Thoughts?

Why LPA? Do you IPL w/ CLPA frequently?

--
Binyamin Dissen <[email protected]> http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to