Just thought I would let you know what happened. The Client application was constantly getting 2c datasets. Therefore, we decided to let SMS control the allocation by setting OVERRIDE SPACE YES. This allowed the user to get their work done.
We are still back tracking in the client-mainframe process to see where the 2 cyl dataset was coming from. Once we fix that, we will change the OVERRIDE SPACE to No. Thanks for all of the suggestions. Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Vernooij, CP (ITOPT1) - KLM > Sent: Tuesday, March 17, 2015 8:11 AM > To: [email protected] > Subject: Re: SMS ACS and TEMP DSN Parsing > > Well, the temp-dsn pattern will probably only change with z/OS releases, so > it will (only) be another item on that checklist. > > Kees. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Lizette Koehler > Sent: Tuesday, March 17, 2015 3:34 PM > To: [email protected] > Subject: Re: SMS ACS and TEMP DSN Parsing > > Yes, that I understand. However, I have always been reluctant to set any > TEMP DSN different than other TEMP DSNs. But this is a unique case and I > am hoping this will resolve the issue. > > The other issue is the consistency for the temp DSN pattern. If anything > changes, this code will no longer work. (Sigh) > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:IBM- > [email protected]] > > On Behalf Of Greg Shirey > > Sent: Tuesday, March 17, 2015 7:30 AM > > To: [email protected] > > Subject: Re: SMS ACS and TEMP DSN Parsing > > > > I don't think there's anything wrong with the logic, but you know that > most > > attributes of a DATACLAS can be overridden. > > > > Greg Shirey > > Ben E. Keith Company > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:IBM- > [email protected]] > > On Behalf Of Lizette Koehler > > Sent: Monday, March 16, 2015 7:02 PM > > To: [email protected] > > Subject: SMS ACS and TEMP DSN Parsing > > > > I am trying to create a process in the Dataclas that will change some > > of > the > > dataset attributes of on specific Temp DSN. > > > > The DSN comes in with DSTYPE = TEMP > > > > Does anyone know if this will work? The DSN will look like this: > > SYS15070.T105514.RA000.MYDSN1.R0226931 > > > > > > If (&DSTYPE = Temp and &DSN(4) = 'MYDSN1') > > Then > > Do > > Set Dataclas = X > > Write DSN set to X Dataclas > > Exit > > End > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN