Could there be a restriction from VM perspective for a certain Volume to be
not shared as WRITE ?


On Tue, Aug 19, 2014 at 7:55 PM, Jake anderson <[email protected]>
wrote:

> q da TCHN01
> DASD 966F CP SYSTEM TCHN01   57    SHARED
>   966F is the real address
>
>
>
> On Tue, Aug 19, 2014 at 7:49 PM, Binyamin Dissen <
> [email protected]> wrote:
>
>> What does Q V addr show?
>>
>> On Tue, 19 Aug 2014 19:38:57 +0530 Jake anderson <
>> [email protected]>
>> wrote:
>>
>> :>Hi,
>> :>
>> :>MVS guest directory has the volume in READ/WRITE and also the security
>> :>access to the Volume has been enabled to access as WRITE. After the
>> Change
>> :>the MVS guest and it  was also IPLed to pick up the changes.(But still
>> no
>> :>luck)
>> :>
>> :>
>> :>On Tue, Aug 19, 2014 at 7:32 PM, John P Kalinich <[email protected]>
>> wrote:
>> :>
>> :>> WRI is write inhibited or read-only.  Check your VM sharing options.
>> :>>
>> :>> Regards,
>> :>> John K
>> :>>
>> :>> IBM Mainframe Discussion List <[email protected]> wrote on
>> :>> 08/19/2014 08:57:41 AM:
>> :>>
>> :>> > From: Jake anderson <[email protected]>
>> :>> > To: [email protected]
>> :>> > Date: 08/19/2014 08:57 AM
>> :>> > Subject: Re: Dataset update error from MVS guest
>> :>> > Sent by: IBM Mainframe Discussion List <[email protected]>
>> :>> >
>> :>> > Hi John,
>> :>> >
>> :>> > IOS000I 0F81,2D,WRI,E7,0200,,06820003,TCHN01,JAKE099  , 855
>> :>> >  800200006F0000000000000000000014081218D156000F0000004CE000000000
>> :>> >
>> :>> >
>> :>> > On Tue, Aug 19, 2014 at 7:15 PM, John P Kalinich <[email protected]>
>> :>> wrote:
>> :>> >
>> :>> > > What IOS000I message did you receive?
>> :>> > >
>> :>> > > Regards,
>> :>> > > John K
>> :>> > >
>> :>> > > Jake A of the IBM Mainframe Discussion List <
>> [email protected]>
>> :>> > > wrote on 08/19/2014 08:22:35 AM:
>> :>> > >
>> :>> > > > From: Jake anderson <[email protected]>
>> :>> > > > To: [email protected]
>> :>> > > > Date: 08/19/2014 08:22 AM
>> :>> > > > Subject: Dataset update error from MVS guest
>> :>> > > > Sent by: IBM Mainframe Discussion List <
>> [email protected]>
>> :>> > > >
>> :>> > > > Hi,
>> :>> > > >
>> :>> > > > I am trying to update a dataset but I receive the below error :
>> :>> > > >
>> :>> > > > IEC212I 414-04,IFG0201R,JAKE099,PROC099,ISP09114,0F81,TCHN01,
>> :>> > > > TCHN01.ASM.DATA
>> :>> > > > ***
>> :>> > > >
>> :>> > > > IBM manual says :
>> :>> > > >
>> :>> > > > Explanation
>> :>> > > > 04
>> :>> > > > An I/O error occurred writing a DSCB during processing of a
>> CLOSE
>> :>> macro
>> :>> > > > instruction.
>> :>> > > >
>> :>> > > > I am trying to update this dataset from a MVS Guest running
>> over a
>> :>> VM.
>> :>> > > The
>> :>> > > > DASD are shared and I have connected the Volume to MVS guest as
>> :>> > > READ/WRITE
>> :>> > > > but still I get this error.
>> :>> > > >
>> :>> > > > MVS guest is running at Z/OS 1.13.
>> :>> > > >
>> :>> > > >
>> :>> > > > One of a link from Google I took :
>> :>> > > >
>> :>> > > > ABEND 414-04 Mean?
>> :>> > > >  Ran into this one recently and I thought I'd share.
>> Essentially, a
>> :>> > > volume
>> :>> > > > can be set to READ ONLY. This is something outside the scope of
>> any
>> :>> > > > security product that might be running on the system, meaning
>> you may
>> :>> > > have
>> :>> > > > RACF permissions to a data set, but if the volume on which that
>> data
>> :>> set
>> :>> > > > resides is READ ONLY, you'll get the 414 abend. The solution is
>> to
>> :>> get
>> :>> > > your
>> :>> > > > system programmer to un-read only the volume so you can write
>> to it.
>> :>> > > >
>> :>> > > > I was also looking at :
>> :>> > > > http://www-01.ibm.com/support/docview.wss?uid=swg1PK37533
>> :>> > > >
>> :>> > > > But not sure if it is really matches the error that I am
>> getting.
>> :>> > > >
>> :>> > > >
>> :>> > > > Any thoughts or suggestion on the above.
>> :>> > > >
>> :>> > > > Regards,
>> :>> > > > Jake
>> :>>
>> :>> ----------------------------------------------------------------------
>> :>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>> send email to [email protected] with the message: INFO
>> IBM-MAIN
>> :>>
>> :>
>> :>----------------------------------------------------------------------
>> :>For IBM-MAIN subscribe / signoff / archive access instructions,
>> :>send email to [email protected] with the message: INFO IBM-MAIN
>>
>> --
>> Binyamin Dissen <[email protected]>
>> http://www.dissensoftware.com
>>
>> Director, Dissen Software, Bar & Grill - Israel
>>
>>
>> Should you use the mailblocks package and expect a response from me,
>> you should preauthorize the dissensoftware.com domain.
>>
>> I very rarely bother responding to challenge/response systems,
>> especially those from irresponsible companies.
>>
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
>>
>
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to